Skip to content
Open access

Research on Energy-Saving Renovation of Building Envelope Structures in Rural Areas of Central Plains of China

Sep 2026 · Buildings · 0 citations

Abstract

Rural residential buildings in China’s Central Plains region suffer from poor envelope thermal performance, resulting in severe thermal discomfort and excessive energy consumption for both winter heating and summer cooling. This study presents a systematic three-in-one envelope retrofit strategy (roof, exterior walls, and windows, with supplementary door replacement) tailored to the region’s cold climate zone (GB 50176-2016, Zone IIB; HDD18 = 2309 °C·d, CDD26 = 131 °C·d), which experiences hot summers and cold winters and thus requires both effective winter insulation and summer heat protection, utilizing cost-effective materials suitable for rural construction. A typical brick-concrete rural residence in Anyang was selected as the case study building. Field measurements of indoor thermal conditions were conducted over 72 h in winter to characterize baseline performance. An Ecotect simulation model was developed and calibrated against measured data using actual hourly meteorological observations from the Anyang National Meteorological Station for the monitored period; the CSWD Typical Meteorological Year (TMY) file was used for the annual simulation. To address concerns regarding discontinued software, key annual load results were cross-validated against an independent EnergyPlus v22.2 model using identical geometry and envelope inputs, yielding agreement within 5%. The proposed retrofit scheme retains the existing 240 mm solid brick walls, adds external insulation consisting of 100 mm EPS panels for walls and 50 mm XPS panels installed at ceiling level within the attic (without disturbing the existing asbestos-cement roof sheeting, in accordance with strict asbestos-handling protocols) for roofs, and replaces single-glazed windows with 6 + 12A + 6 insulated hollow glass units. The results demonstrate that the optimized envelope significantly reduces overall heat transfer coefficients: wall U-value decreases from 1.79 to 0.32 W/(m2·K), roof U-value from 2.46 to 0.48 W/(m2·K), and window U-value from 6.40 to 2.40 W/(m2·K). The passive adaptability index (PAI)—the annual proportion of free-running hours within the fixed 18–28 °C screening band specified in Table 4.3.1 of GB/T 50785-2012—improves from 0.41 to 0.68, and annual heating and cooling energy consumption is reduced by 50.4% (49.6% when the supplementary door replacement is excluded; (123 − 62)/123 = 49.6%). Under this fixed-band screening criterion, indoor operative temperature lies within the band for 68% of annual hours, compared with 41% in the baseline; these figures are fixed-temperature-range screening results rather than a formal adaptive-comfort evaluation (Section 3.3 and Section 6.3). A Glaser method condensation analysis confirms no interstitial condensation risk in the externally insulated EPS wall assembly. This study provides validated, region-specific technical parameters and demonstrates that a coordinated three-component envelope retrofit can achieve over 50% energy savings while substantially improving indoor thermal conditions as measured by the fixed 18–28 °C screening band in rural Central Plains buildings; a formal adaptive thermal comfort evaluation was not conducted and is identified as future work (Section 3.3 and Section 6.3). The material-cost-based simple payback is approximately 5.5 years (CNY 19,500 ÷ CNY 3550/year); including estimated rural labor and scaffolding costs (CNY 4000), the full project payback is approximately 6.6 years (CNY 23,500 ÷ CNY 3550/year). The findings offer practical guidance for large-scale rural building energy retrofitting programs in cold climate zones of China with transitional characteristics.

Read PDF

Similar papers

Open access Oct 2026

Assessment and Improvement Strategies for the Winter Indoor Thermal Environment of Temporary Construction-Site Buildings in Cold Regions

Temporary construction-site buildings in cold regions often suffer from poor indoor thermal environments and high heating energy consumption, while field-based studies and cost-effective improvement strategies remain limited. This study investigated typical office and dormitory temporary buildings in Yan’an, China, usi...

Hai-Si Zheng, Wen-Lai Li, Hong-Xia Yang et al. · 0 citations
Open access Oct 2026

Heat transfer characteristics and energy performance of lightweight building envelopes in hot summer and warm winter regions

: This study investigates the application of an EPS light-gauge steel composite envelope system in rural buildings located in the hot-summer and warm-winter region of Hainan. An experimental building was constructed in Shitang Village, Ding’an County, Hainan Province, using traditional brick structures as a control for...

Li Li, Da-Wei Mu, Jiao-Jiao Cheng · 0 citations
Review Open access Oct 2026

Research on the Performance and Regional Applicability of Rural Clean Heating Systems in Jilin Province, China

Rural heating renovation in Jilin Province requires systems that suit regional conditions while balancing household costs and indoor thermal conditions. This study combined a survey of 276 rural households with TRNSYS multizone simulations to assess five heating configurations in Yanji, Changchun, and Baicheng, China....

Tian-Xiu Zhao, Tian-Yang Zhang, Hong-Hui Teng et al. · 0 citations
Sep 2026

How do high-insulation buildings influence cooling energy consumption and the outdoor thermal environment? A multi-scale analysis in China's severe cold regions

Climate change is intensifying summer overheating and cooling energy demand, even in China's severe cold regions, where residential building design has historically prioritized winter thermal insulation. This study investigates how envelope insulation levels affect indoor overheating, cooling energy consumption, and...

Yu-Han Zhao, Bo-Lun Zhao, Chen Wang et al. · 0 citations
Open access Oct 2026

Simulation Study on the Performance Assessment of a Direct-Expansion Solar PV/T Coupled Air-Source Heat Pump System for Rural Buildings in Typical Climate Zones of China

The direct-expansion solar photovoltaic/thermal (PV/T) coupled air-source heat pump (ASHP) system is an integrated technology for the combined domestic hot water and electricity supply of rural buildings, but the variation in its performance across climate zones limits confidence in its large-scale deployment. In this...

Hao-Ran Ning, Bin Zhong, Ze-Xuan Wang et al. · 0 citations
Open access Oct 2026

Research on Energy-Saving Optimization of Civil Hotel Envelope in Hot Summer and Cold Winter Zone Based on DeST

Aiming at the energy consumption issues of civil hotels, this study takes a hotel in Shanghai as an example and uses DeST simulation and orthogonal tests to analyze the effects of exterior wall insulation thickness (60-100 mm) and window materials (common insulating glass, Low-E coated low-emissivity insulating glass,...

Ming-Hui Sun · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.