Skip to content
Open access

Ruptured INfrarenal abdominal AneurySm: aortiC repair using the ENduranT Endograft. The R.IN.AS.C.ENT.E. Study.

Nov 2026 · Journal of Endovascular Therapy · pp. 15266028261497972 · 0 citations · 13 references
Medicine

TL;DR

The findings support the use of Endurant devices in emergent settings for anatomically suitable patients and reinforce EVAR-first strategies in the management of ruptured abdominal aortic aneurysms and emphasize the importance of device-specific outcome assessment in emergent rAAA repair.

Abstract

Background

Ruptured abdominal aortic aneurysm (rAAA) represents a vascular surgical emergency with high mortality. Endovascular aneurysm repair (EVAR) using the bifurcated Endurant stent graft system is widely employed; however, data specifically addressing its performance in infrarenal rAAA remain limited.

Methods

We conducted a retrospective, multicenter study including 121 patients with confirmed infrarenal rAAA treated exclusively with bifurcated Endurant II or IIs (Medtronic Inc., Minneapolis, Minnesota) devices across 5 Italian tertiary vascular centers from January 2014 to October 2024. Primary endpoints were technical success and 30-day all-cause mortality. Secondary outcomes included long-term survival, incidence of endoleaks, and reintervention rates. Patients receiving alternative stent grafts or hybrid procedures were excluded to ensure cohort homogeneity.

Results

A total of 121 patients were enrolled during the study period. The cohort had a mean age of 75.3 ± 8.2 years, with 91.7% male predominance. Technical success was achieved in 96.7%. The 30-day mortality rate was 15.7%. Multivariate logistic regression identified abdominal compartment syndrome (ACS) (odds ratio [OR], 29.8; 95% confidence interval [CI], 2.8-317.7; P = .005) and use of an aortic occlusion balloon (AOB) (OR, 16.4; 95% CI, 2.5-106.2; P = .003) as independent predictors of early mortality. At a median follow-up of 33.6 months (interquartile range, 4.9-72.3), 5-year survival was 65.4%, freedom from any endoleak was 92.6%, and freedom from reintervention was 91.6%. Late type Ia endoleaks occurred in 2.5% of patients.

Conclusions

In this large, strictly defined infrarenal rAAA cohort, bifurcated Endurant stent grafts demonstrated high technical success and favorable early and mid-term clinical outcomes, including in patients with hostile neck anatomy. Early identification and management of ACS and judicious use of AOBs may improve survival. These findings reinforce current EVAR-first guidelines and emphasize the importance of device-specific outcome assessment in emergent rAAA repair.Clinical ImpactThis multicenter study provides one of the largest device-specific evaluations of bifurcated Endurant stent grafts for infrarenal ruptured abdominal aortic aneurysms in a rigorously defined Italian cohort, demonstrating high technical success (96.7%) and low 30-day mortality (15.7%) despite a high prevalence of hostile neck anatomy (54.5%). Abdominal compartment syndrome and the use of an aortic occlusion balloon emerged as independent predictors of early mortality, highlighting the critical role of perioperative management. Mid-term outcomes were favorable, with a 5-year survival rate of 65.4%, a low incidence of type Ia endoleak (2.5%), and high freedom from reintervention (91.6%). Overall, these findings support the use of Endurant devices in emergent settings for anatomically suitable patients and reinforce EVAR-first strategies in the management of ruptured abdominal aortic aneurysms.

Read PDF

Similar papers

Open access Oct 2026

Outcomes of endovascular repair for infrarenal abdominal aortic aneurysm at the Cardiovascular Center, E Hospital: a case series and multi-center data comparison

Endovascular aneurysm repair is a feasible procedure providing high survival rates and effective aneurysm exclusion, however, access-site vascular complications and Type I endoleaks remain significant limitations.

T. Phan, Thế Huy Nguyễn, Duc Ngoc Ly et al. · 0 citations
Open access Oct 2026

Early and follow-up results of reinterventions for type 2 endoleak following endovascular repair of abdominal aortic aneurysm (EVAR): the multicenter REinterventions for Type 2 Endoleak (RETE) study.

BACKGROUND Type II endoleak (T2EL) is frequent after endovascular abdominal aortic aneurysm repair (EVAR) and may require reintervention in selected patients. However, the optimal treatment strategy for durable resolution remains uncertain. The aim of this study is to retrospectively analyze perioperative and long-term...

R. Falso, S. Speziali, P. Perini et al. · 0 citations
Open access Oct 2026

1-Year Outcomes of Endovascular Repair of Zone 0/1 Aortic Arch Lesions with a Thoracic Branched Endoprosthesis.

BACKGROUND The GORE® TAG® Thoracic Branch Endoprosthesis (TBE) pivotal non-randomized, multicenter, prospective trial evaluated 1-year outcomes in patients at high risk for open surgical repair undergoing aortic arch and descending thoracic aorta endovascular repair (Zone 0/1). METHODS Endpoints evaluated from endova...

William T. Brinkman, W. Shutze, Dennis Gable et al. · 0 citations
Open access Nov 2026

Transcatheter coil embolization for proximal thoracic aortic pseudoaneurysms: a case series with mid-term clinical and imaging follow-up.

OBJECTIVES Proximal aortic pseudoaneurysms represent a life-threatening complication of cardiac surgery. Traditional redo surgery is associated with substantial operative risk, while conventional endovascular stenting is often precluded by complex anatomy. We evaluated the clinical feasibility, safety, and durability o...

L. Di Marco, A. Piperata, S. Snaidero et al. · 0 citations
Open access Sep 2026

TEVAR for Nontraumatic Ruptured Type B Aortic Dissections: A European Multicentre Study.

OBJECTIVE Ruptured acute type B aortic dissection (TBAD) is rare, carries high mortality risk, and presents major challenges with limited supporting evidence. This study evaluated early and mid-term outcomes after thoracic endovascular aortic repair (TEVAR) for nontraumatic ruptured TBAD. METHODS This retrospective m...

E. Lilja, K. Mani, A. Wanhainen et al. · 0 citations
Oct 2026

Early and midterm outcomes of the Gore Excluder Iliac Branch Endoprosthesis within and outside the instructions for use for aortoiliac and iliac artery aneurysms.

OBJECTIVE To evaluate perioperative and midterm outcomes of endovascular aneurysm repair using the Gore Excluder Iliac Branch Endoprosthesis (IBE) for aortoiliac and iliac artery aneurysms treated within and outside the instructions for use (IFU). METHODS This single-center retrospective cohort study included patient...

Masayuki Hara, Kentaro Kasa, Takao Ohki et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.