Jul 2026· Frontiers in Energy Research· Vol 14· 0 citations· 28 references
Abstract
To address the difficulty in accurately detecting and locating single-phase-to-ground faults in active distribution networks under random fluctuations of distributed energy resources and disturbances, this paper proposes a fault sensing and section location method based on the linear eigenvalue statistics of zero-sequence voltage. Firstly, from the perspective of high-dimensional space, the advantages of zero-sequence voltage in constructing fault sensing and location methods are analyzed. Secondly, a sliding window data matrix of node zero-sequence voltage and its covariance matrix are constructed, and the linear eigenvalue statistics are used to sense the fault occurrence time. Faulted-section localization is achieved based on the node contribution of abnormal eigenvectors and the difference index between adjacent nodes. Simulation verification is carried out on a 33-node distribution network under complex disturbance scenarios including no access of distributed generation, access of distributed generation, and neutral grounding via an arc suppression coil. The results show that the proposed method can effectively identify the occurrence time of single-phase-to-ground faults and achieve high-precision faulted-section localization under complex disturbance conditions.
To address the issue of ambiguous fault localization in multi-branch active distribution networks (ADN) caused by the weak characteristics of single-phase high impedance faults (HIF) and interference from distributed generation (DG), a fault section location method integrating multi-source transient features and topolo...
Zhe-Nang Zhang, Na Wu, Shu-Xian Fan· 2026 6th International Confe...· 0 citations
A feature-distance-weighted dynamic localization algorithm is designed, incorporating a multi-node time-series coordination mechanism to update location results, which validates the effectiveness of frequency-energy feature analysis for distribution ground fault location.
Ke-Yu Yue, Yu Zheng, Zhi-Gang Wang et al.· European Conference on Elect...· 0 citations
Complex distribution-network topologies limit the accuracy of traveling-wave fault location, because the zero-mode velocity decays nonlinearly while conventional double-ended methods still require synchronized clocks. A clock-offset-invariant multi-terminal scheme combining mathematical morphology (MM), support vector...
Dong-Mei Liu, Kai Zeng, Cheng-Wei Luo et al.· Symmetry· 0 citations
With the increasing adoption of bipolar high-voltage direct-current (HVDC) transmission lines for wind farm integration, the development of fast, accurate, and communication-independent protection schemes has become a critical technical requirement. This paper proposes a comprehensive protection algorithm within an int...
Mahyar Abasi, Vahid Davatgaran, Morteza Azizi· PLoS ONE· 0 citations
In this paper, a single fault-diagnosis framework of electrical systems operating under non-stationary conditions is proposed. The algorithm is a hybrid of spectral analysis with Short-Time Fourier Transform (STFT) and adaptive time-frequency analysis with Hilbert-Huang Transform (HHT) to obtain complimentary fault-rel...
Nadir E. Mohamed, Md Shafiullah, M. Hussan· Jordan journal of electrical...· 0 citations
Electric transmission is a key component in the powertrain of heavy vehicles. Due to its highly compact component layout and complex operational environment, fault features in vibration signals are easily overwhelmed by noise. To address this issue, this paper proposes a fault localization method that combines modal de...
Shu-Feng Lin, Chang-Song Zheng, Cen-Bo Xiong et al.· International Conference on...· 0 citations