Oct 2026· Proceedings of the Institution of mechanical engineers. Part C, journal of mechanical engineering science· 0 citations· 24 references
Abstract
Erosion in elbows is a critical factor affecting the safety and service life of heat-exchange pipelines. To elucidate the erosion patterns of 90° elbows in heat-exchanger tubes under solid–liquid two-phase flow, this study conducts a systematic investigation combining experimental measurements with numerical simulations. An erosion test rig was first designed and constructed, and specimens were arranged at different positions on the inner wall of the elbow to investigate the effects of flow velocity, particle diameter, erosion duration, and specimen orientation on the erosion rate. These tests identified the primary influencing factors and their roles. Due to experimental limitations in capturing minor erosion and evaluating structural parameters, a Fluent-EDEM coupled model based on the Eulerian-Lagrangian approach was further established to simulate the erosion characteristics in the elbow. The numerical results were validated against experimental data, demonstrating the reliability of the model. The simulations provide flow-field and erosion information difficult to obtain experimentally and systematically reveal the effects of flow velocity, particle properties, and geometric parameters on erosion distribution and local erosion intensity. This study enhances the understanding of elbow erosion mechanisms and offers a theoretical basis for the structural optimization of heat-exchange tubes under particle-laden flow conditions.
Improving the energy efficiency of thermal systems has become increasingly important for the development of compact and high‐performance heat exchangers (HEs). Among various passive enhancement techniques, twisted‐tape inserts have demonstrated significant potential for improving heat transfer without additional ener...
Brajesh Kumar Ahirwar, M. Diwaker· Heat Transfer· 0 citations
Localized erosion near the valve cover and pin shaft can impair the reliability of drilling float valve. This study investigates an eccentric contraction modification for a 62 mm float valve, in which the small-end cross-section is shifted away from the pin shaft while the diameters of both end sections remain unchange...
Xin Zhang, Ju-Nan Lu, Yan-Wen Liu et al.· Processes· 0 citations
Acid-etched fracture conductivity testing (AFCT) is a key technique for evaluating the effectiveness of acid fracturing, but the existing test apparatus still presents many problems. One of these problems is the sudden expansion at the connection part, which leads to flow instabilities. To address the limitations of th...
Hui-duck Han, Huan Peng, Jian Yang et al.· Applied Sciences· 0 citations
The removal of decay heat is essential for safety in nuclear power plants, with the Passive Residual Heat Removal System (PRS) serving as a key design feature. The adoption of natural-draft air-cooled heat exchangers provides sustained heat removal without a specified time limit; in these systems, the air-side thermal...
Li-Yu Zhang, Qi-Hang Zhang, Chen-Hang Tang et al.· Journal of Nuclear Engineeri...· 0 citations
This study investigates the failure mechanism of a cracked piping elbow in a crude-oil transport system after approximately 20 years of service, with the aim of identifying the dominant degradation mechanisms and assessing structural integrity using numerical and risk-based approaches.
The study combines fie...
M. Jarić, S. Petronić, Z. Brat et al.· International Journal of Str...· 0 citations