Skip to content
Open access

Targeting Higher Order Aberrations Alone in Keratoconus: A Tissue-Saving Alternative to Established Protocols.

Aug 2026 · Journal of refractive surgery · Vol 42 8, pp. e841-e851 · 0 citations · 10 references
Medicine

TL;DR

Treating only the sphere and cylinder embedded into the HOA ablation treatment profile leads not only to the slimmest ablation depth over the cone and ablation volume, but, more importantly, it provides the lowest increase in ablation depth with enlargement of the OZ.

Abstract

Purpose

To evaluate cone stromal ablation depth with varying optical zones using different customized ablation strategies in keratoconus.

Methods

This retrospective computational analysis assessed 59 eyes from 59 patients with mild to moderate keratoconus using three different simulation approaches. The first approach involved treating the full manifest refraction along with the corneal higher order aberrations (HOAs). The second approach, following the Athens Protocol, targeted all HOAs with up to 70% correction of the cylinder and sphere, limiting cone stromal ablation to 50 µm at an optical zone (OZ) of 5.5 mm. The third approach treated all HOAs and included only the sphere and cylinder embedded within the HOA ablation profile, as calculated by the ORK CAM software for the SCHWIND AMARIS (SCHWIND eye-tech-solutions GmbH). All models were simulated on the ORK module, with OZ ranging from 5.5 to 7 mm. The primary outcome measure was the mean stromal ablation depth over the cone and was calculated for all possible scenarios.

Results

In approach #1, the mean cone stromal ablation depths and ablation volumes were 49 ± 28, 58 ± 34, 68 ± 40, and 77 ± 46 µm, and 1,074 ± 626, 1,460 ± 863, 1,906 ± 1,113, and 2,448 ± 1,451 nl for an OZ of 5.5, 6, 6.5, and 7 mm, respectively (P < .001). Approach #2 yielded mean depths and volumes of 33 ± 13, 38 ± 15, 44 ± 17, and 50 ± 19 μm, and 686 ± 266, 939 ± 371, 1,240 ± 489, and 1,592 ± 669 nl, respectively (P < .001). In approach #3, the corresponding depths and volumes were 15 ± 6, 17 ± 7, 19 ± 7, and 21 ± 8 µm and 279 ± 89, 377 ± 118, 491 ± 146, and 626 ± 205 nl, respectively, across the same OZ range (P < .001). There was a significant difference in mean cone stromal ablation depths and ablation volumes among the three approaches across all OZs, with approach #3 consistently demonstrating the lowest ablation depths and ablation volumes (P < .001). Furthermore, the rate of increase in mean stromal ablation depth over the cone with expanding OZ size was minimal in approach #3.

Conclusions

Treating only the sphere and cylinder embedded into the HOA ablation treatment profile leads not only to the slimmest ablation depth over the cone and ablation volume, but, more importantly, it provides the lowest increase in ablation depth with enlargement of the OZ.

Read PDF

Similar papers

Open access Aug 2026

Outcomes of higher-order aberration correction in relation to optical zone size after Phorcides-planned laser in situ keratomileusis in Indian Eyes.

PURPOSE To evaluate the influence of additional ablation (Abl-max) on higher-order aberrations (HOAs), particularly corneal coma, following Phorcides-planned topography-guided laser in situ keratomileusis (LASIK) in an Indian population. METHODS We analyzed 161 eyes of 83 patients undergoing Phorcides-planned topogra...

Tanvi Haldipurkar, Mayur Phatak, Seema Bhosale et al. · 0 citations
Open access Sep 2026

Establishing a precision reference benchmark for corneal epithelial aberration measurements using a new hybrid device across keratoconus stages

The new MS-39 device demonstrated moderate-to-good precision in corneal epithelial aberration measurements for FFKC, mild, moderate and total KC, and the potential of the device for early diagnosis and monitoring was still evident.

Yi-Zhou Yang, Rui Ning, Si-Heng Li et al. · 0 citations
Review Aug 2026

Induced Ocular Higher-Order Aberrations After Photorefractive Keratectomy versus Laser-Assisted In Situ Keratomileusis for Myopia: A Systematic Review and Meta-Analysis.

The overall PRK advantage in total ocular HOAs is small and dependent on ablation profile and platform rather than procedure type alone, and wavefront-guided PRK may offer a modest optical advantage over LASIK, while wavefront-optimized outcomes are less certain.

K. Sadek, A. Alizada, Salem Abu Al-Burak et al. · 0 citations
Review Open access Sep 2026

Management of astigmatism in keratoconus with therapeutic refractive surgery

Current therapeutic refractive strategies are best viewed within an individualized, phenotype-driven framework rather than a mandatory linear sequence, and future progress will depend on multimodal imaging, improved phenotyping, and more individualized corneal shape-restoration strategies.

Hao Zhang, J. L. Alio Del Barrio, Qing-Luan Bao et al. · 0 citations
Sep 2026

Refractive and corneal analyses after custom-Q versus wavefront-optimized ablation in photorefractive keratectomy for myopia.

PurposeTo evaluate refractive and tomographical outcomes following Custom-Q without Q-adjustment and wavefront-optimized (WFO) photorefractive keratectomy (PRK) for myopia.MethodsThis retrospective, comparative study included 46 eyes in the Custom-Q group and 40 eyes in the WFO group who underwent PRK for myopia and/or...

Burak Tanrıverdi, N. Çağıl · 0 citations
Open access Aug 2026

A comparative analysis of predicted spherical refractive outcomes between two swept-source optical biometers.

PURPOSE To compare the predicted spherical equivalent (PSEq) between the ANTERION® anterior segment OCT device (Heidelberg Engineering GmbH, Heidelberg, Germany) and the IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany) in patient undergoing cataract surgery. METHODS Ocular biometry was performed by a single inves...

Samir Uprety, C. McLintock, Saran Takemura et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.