Aug 2026· ACS Applied Materials and Interfaces· Vol 18 32, pp.
43775-43784
· 2 citations· 37 references
Medicine
TL;DR
This work provides a general design methodology for the synergistic regulation of field distributions and modal characteristics in asymmetric electromagnetic structures, establishing a robust technical foundation for the development of high-performance, anatomically conformal clinical MRI hardware.
Abstract
Improving the signal-to-noise ratio (SNR) is crucial for enhancing image quality and diagnostic reliability in magnetic resonance imaging (MRI). However, traditional methods that rely on increasing the number of coil channels are approaching their physical and engineering optimization limits. In recent years, wireless, passive metamaterials have been explored for local magnetic field enhancement via radiofrequency field modulation, offering a new pathway to improve SNR. However, the regular configurations of most existing metamaterial structures hinder their conformance to anatomical contours, thereby limiting the spatial filling factor and preventing further SNR enhancement, while anatomically conformal designs often result in nondegenerate orthogonal modes. This study presents a conformal elliptical cylindrical metamaterial designed to achieve uniform magnetic-field enhancement and restore orthogonal-mode degeneracy in a non-axisymmetric geometric configuration. This is achieved through cross-sectional gradient impedance design and end-ring impedance tuning. Additionally, nonlinear response control is introduced to eliminate interference with the radiofrequency transmit field. Experimental results show that, when used in various clinical imaging sequences, the metamaterial yields wrist MR images with an SNR more than 4 times that obtained with a commercial flexible coil. This work provides a general design methodology for the synergistic regulation of field distributions and modal characteristics in asymmetric electromagnetic structures, establishing a robust technical foundation for the development of high-performance, anatomically conformal clinical MRI hardware.
Metasurfaces offer a promising approach to enhance the signal-to-noise ratio (SNR) in magnetic resonance imaging (MRI). Thyroid MRI suffers from insufficient SNR due to the anatomical irregularity of the neck and poor coil-to-tissue proximity, which fails to meet the demands of preoperative tumor diagnosis. This work i...
Zhiang Wang, Zhong-Hai Chi, Xin-Xin Li et al.· ACS Applied Materials and In...· 0 citations
The accuracy of quantitative magnetic resonance imaging (qMRI) largely depends on the image signal‐to‐noise ratio (SNR). In recent years, studies on metamaterials in MRI have shown that they can significantly improve image quality through weak coupling with the body coil or receive coil. However, it is still unclear...
Ya-Kui Wang, Ying-Yi Qi, Bing Liu et al.· Advanced Physics Research· 0 citations
PURPOSE
Ultra-high field (≥ 7 T) and 3 T MRI suffer from B1 + inhomogeneity and signal loss. Conventional metasurfaces that mitigate B1 + inhomogeneity and improve image SNR are "fixed" in nature and designed for a single Larmor frequency. This study demonstrates the feasibility of an adaptive metasurface utilizing vol...
Paul S. Jacobs, Pradnya Narvekar, Neil E. Wilson et al.· Magnetic Resonance in Medici...· 0 citations
Wrist magnetic resonance imaging (MRI) is essential for evaluating soft‐tissue injury, bone marrow edema, and small‐joint abnormalities, yet high‐quality imaging still relies largely on dedicated wrist coils and often requires the uncomfortable prone “superman” position. Here, we present a clinically adaptive gradien...
The wireless metasurface coil was more convenient and provided image quality and diagnostic performance comparable to the 12-channel commercial knee coil at 1.5 T.
Jie Gao, Xin-Xin Li, Zhong-Hai Chi et al.· Journal of Magnetic Resonanc...· 1 citation
Ultrasound imaging has been extensively employed in biomedical diagnosis and clinical research, owing to its compelling merits of non-ionizing radiation, cost-effectiveness, and real-time visualization. However, conventional ultrasound imaging systems are fundamentally constrained by diffraction-limited spatial resolut...
Jia-Jie He, Jun-Hao Jiang, Hai-Jun Luo et al.· Chinese Physics B· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.