Complications and Maintenance of Mandibular Two-implant Overdentures: A 3-year Pilot Randomized Clinical Study of Bar–Locator Versus Bar–Ball Attachments
Jul 2026· European Journal of Dentistry· 0 citations· 40 references
Medicine
TL;DR
Both attachment systems demonstrated frequent but manageable prosthetic complications over the 3-year follow-up period, with no statistically demonstrable superiority between designs within the limitations of this pilot study.
Abstract
Abstract Objective This 3-year pilot randomized clinical study aimed to compare prosthetic complications and maintenance requirements of mandibular two-implant overdentures retained by bar–locator and bar–ball attachment systems. Materials and Methods A total of 10 completely edentulous participants were randomly allocated to receive mandibular overdentures retained by either bar–locator ( n = 5) or bar–ball ( n = 5) attachment systems. All participants received new complete dentures before implant placement. Two implants were inserted in the inter-foraminal region and restored with the assigned bar-retained attachment. Prosthetic complications and maintenance events were recorded during scheduled follow-up visits over 3 years. Evaluated outcomes included retentive component wear, attachment separation, screw loosening, denture tooth and base complications, opposing prosthesis fractures, and relining requirements. Statistical Analysis Descriptive statistics, Fisher's exact test, independent samples t-tests, effect sizes, and confidence intervals were used for analysis, with emphasis placed on estimation rather than formal hypothesis testing. Results No statistically significant differences were observed between attachment systems for individual prosthetic complications. Retentive component wear was the most common complication and occurred more frequently in the bar–locator group, whereas denture relining was more common in the bar–ball group. Although the mean number of complications per patient was higher with bar–locator attachments, the difference did not reach statistical significance. However, the large effect size suggested a potentially clinically meaningful increase in maintenance burden associated with bar–locator systems. Conclusion Both attachment systems demonstrated frequent but manageable prosthetic complications over the 3-year follow-up period, with no statistically demonstrable superiority between designs within the limitations of this pilot study. Bar–locator attachments were associated mainly with retentive component wear, whereas bar–ball attachments showed greater relining requirements. No catastrophic mechanical failures were observed, supporting the clinical reliability of both systems. These preliminary findings may assist in the design and sample size estimation of future adequately powered clinical trials.
This randomized controlled crossover trial evaluated the mechanical
reliability, cumulative tooth debonding rates, and patient-reported
satisfaction of 3D-printed versus conventionally heat-polymerized complete
dentures over a 12-month period. Forty-eight fully edentulous adults (mean
age 63.7 ± 8.4 years) received bot...
Sultanova Makhsuma, Gaybullaev Azam Akhadovich, Khasan Ibragimov Ismoilovich et al.· European Journal of Prosthod...· 0 citations
Background and Aim: Unfavorable load transfer in implant-retained
overdentures compromises osseointegration and longevity. While the Locator
R-Tx aims to improve durability, its biomechanical impact relative to the
conventional Locator remains understudied. Therefore, this study compared
peri-implant strain between con...
Ahmed Mohamed Hussien, Hafez Ibrahim Bahnasawy, Mostafa I. Fayad et al.· European Journal of Prosthod...· 0 citations
The investigated conometric retention system demonstrated high implant and prosthetic survival rates and limited marginal bone changes, however, a clinically relevant incidence of technical complications, including irreversible loss of conometric retention, was observed during the first year of function.
Peter Gehrke, Octavio Weinhold, Pelayo Antuna et al.· International Journal of Imp...· 0 citations
PURPOSE
Dental implants are a widely used and effective method for tooth replacement, yet complications such as abutment screw loosening remain a challenge. The aim of this study was to investigate the effect of different abutments, connection types and restoration types on abutment screw loosening.
MATERIALS AND MET...
Saman Savabi, F. Nejatidanesh, G. Savabi et al.· The International Journal of...· 0 citations
Objectives: We aim to assess the 5-year clinical outcomes of a cylindrical-conical implant system with a progressive thread design and a sandblasted, acid-etched surface and its fixed prostheses under routine clinical conditions. Methods: This retrospective single-center cross-sectional follow-up study included patient...
This split-mouth randomized controlled trial evaluated the effect of implant surface roughness (hybrid vs. moderately rough) on long-term crestal bone remodeling and peri-implant health. Oral Health-related Quality of Life (OHRQoL) was evaluated after 1 and 8 years. Twenty-four fully edentulous patients received a mand...
S. Matthijs, Maarten Gilbert, Ruben Tilburgh et al.· The international journal of...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.