Assessment and validation of the established free-running framework for cardiac function by magnetic resonance imaging at 1.5T (FAST-CMR): an international multi-center, multi-vendor study.

Aug 2026 · Journal of Cardiovascular Magnetic Resonance · pp. 102784 · 0 citations · 59 references
Medicine

TL;DR

This first prospective international multi-center, multi-vendor evaluation of 5D FISS-FRF can provide measurements that are comparable to conventional 2D cine across diverse clinical settings, while potentially offering improvements in workflow, scan efficiency and patient experience is evaluated.

Abstract

Background

Cardiovascular magnetic resonance (CMR) is the reference standard for assessing cardiac function, yet its widespread clinical use remains challenged by time-intensive workflows requiring ECG gating, repetitive breath-holding, and expert planning. The free-running framework (FRF) addresses these barriers by enabling respiratory and cardiac motion resolved (5D) whole-heart imaging without ECG, breath-holds, or expert scan plane planning. Its fast interrupted steady-state (FISS) variant further enables high quality clinical imaging with gadolinium-based or ferumoxytol contrast agents by providing balanced steady-state free precession (bSSFP)-like contrast with intrinsic fat suppression. The combined 5D FISS-FRF approach, therefore, enables 3D, motion-resolved, free-breathing whole-heart imaging with efficient fat suppression. Early single-center studies have demonstrated feasibility and high concordance with conventional 2D cine imaging, but its generalizability and clinical utility in a multi-center, multi-vendor setting is not yet established. METHODS/

Design

FAST-CMR (Assessment and validation of the established free-running framework for cardiac function by magnetic resonance imaging) is a prospective, observational, intra-individually controlled, pragmatic multi-center study enrolling 300 patients with cardiac disease across 21 international sites from 6 continents using 1.5T MR systems of both Siemens Healthineers and Philips Healthcare. Patients will undergo conventional 2D cine bSSFP CMR in both short-axis and long-axis orientations and a post-contrast 5D FISS-FRF acquisition of six minutes in length. Stratification will include equal representation across three disease cohorts: patients with congenital heart disease (CHD), patients unable to breath-hold, and patients who are able to breath-hold. 5D FISS-FRF raw image acquisition data will undergo centralized reconstruction at the coordinating center (CHUV) before blinded analysis at the core laboratory (Mayo Clinic). The primary endpoint is the precision of the mean paired difference in left ventricular ejection fraction (LVEF) between 5D FISS-FRF and conventional 2D cine CMR, assessed on a within-subject basis. Agreement will be further characterized using confidence intervals for the mean difference and Bland-Altman analysis. Secondary endpoints include detection of regional wall-motion abnormalities, image quality, scan efficiency, patient comfort, LV mass, left and right atrial volumes, and feasibility of automated post-processing and artificial intelligence (AI)-based reconstruction. DISCUSSION/

Conclusion

FAST-CMR will provide the first prospective international multi-center, multi-vendor evaluation of 5D FISS-FRF. By combining standardized acquisition, centralized reconstruction, and harmonized analysis across 21 international sites and two vendor systems, the study will assess the generalizability and robustness of ventricular functional measurements obtained with 5D FISS-FRF. Using a pre-specified precision-based framework for global ventricular function and complementary agreement analyses, FAST-CMR will evaluate whether 5D FISS-FRF can provide measurements that are comparable to conventional 2D cine across diverse clinical settings, while potentially offering improvements in workflow, scan efficiency and patient experience. These results will inform future studies assessing clinical interchangeability with conventional 2D cine imaging and implementation in routine CMR practice.

Read PDF

Similar papers

Open access Aug 2026

Volumetric real-time MRI for the guidance of cardiac catheterization at 0.55T.

Volumetric real-time MRI is feasible for the guidance of invasive procedures such as right-heart catheterization at 0.55T and offers flexible real-time re-slicing, volumetric 3D visualization, and the potential for improved device monitoring.

Prakash Kumar, R. Ramasawmy, A. Javed et al. · 0 citations
Open access Aug 2026

Real-time CMR combined with cardiopulmonary exercise testing enables integrated assessment of cardiac function during exercise

Background Cardiopulmonary exercise testing (CPET) is the gold standard for assessing cardiopulmonary responses to physical stress. Real-time magnetic resonance imaging (RT-MRI) enables continuous cardiovascular imaging during free breathing (FB) and dynamic exercise. Objective This study aimed to develop a clinically...

L. Röwer, Duy Tam Vu, M. A. Goundi et al. · 0 citations
Open access 2026

Native T1 and T2 mapping reference values in a South African population: Scanner-specific calibration on a 1.5 Tesla Siemens Aera system at Tygerberg Hospital

Background: Quantitative myocardial T1 and T2 mapping is integral to cardiovascular magnetic resonance (CMR) imaging. Absolute myocardial relaxation times vary across imaging platforms due to system-specific technical factors. Consequently, mapping reference ranges are not transferable across platforms and require scan...

L. J. Giliomee · 0 citations
Open access Sep 2026

Native myocardial T1 mapping using rapid 1.5T T1FLASH and T1 MOLLI during breath-hold and free-breathing

Quantitative myocardial T1 mapping is an established technique in cardiovascular magnetic resonance (CMR). However, conventional T1 mapping requires relatively long breath-holds (BH), which may lead to breathing artifacts and reduced image quality in patients with limited BH capacity. The T1 fast low angle shot (T1FLAS...

L. Röwer, Yara Hussen-Demir, P. E. Verde et al. · 0 citations
#machine learning Preprint Sep 2026

ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation

Cardiovascular magnetic resonance (CMR) provides comprehensive cardiac assessment but remains underutilized because of the complexity of acquisition, post-processing, and interpretation. Existing artificial intelligence (AI) methods address isolated tasks, limiting clinical integration. We present ORION-CMR (On-scanner...

O. Demirel, Kelly K. Horst, A. Perazzolo et al. · 0 citations
Open access Aug 2026

Pre-Scan Breathing Pattern and Image Quality in Respiratory-Triggered T2-Weighted Liver MRI: Radial Versus Cartesian Fast Spin Echo.

BACKGROUND Respiratory-triggered T2-weighted imaging (T2WI) may use rectilinear sampling (respiratory-triggered fast recovery fast spin echo [RT-FRFSE]) or radial sampling (periodically rotated overlapping parallel lines with enhanced reconstruction [PROPELLER]). Their relative performance across breathing patterns is...

H. Park, Jimi Huh, K. Lee et al. · 1 citation

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.