Skip to content
Open access

High Resolution Isotropic 'Pseudo' 3D Cine imaging with Automated Segmentation using Concatenated 2D Real-time Imaging and Deep Learning.

Jul 2026 · Journal of Cardiovascular Magnetic Resonance · pp. 102780 · 0 citations · 28 references
Medicine

TL;DR

The potential of creating a pseudo 3D-cine data from concatenated 2D real-time cine images using a series of DL models is demonstrated, which has short acquisition and reconstruction times with fully segmented data being available in less than one minute.

Abstract

Background

Conventional cardiovascular magnetic resonance (CMR) in pediatric and congenital heart disease uses 2D, breath-hold (BH), balanced steady state free precession (bSSFP) cine imaging for assessment of function, in addition to cardiac-gated, respiratory-navigated, static 3D bSSFP whole-heart imaging for anatomical assessment. Our aim is to concatenate a stack of 2D free-breathing real-time cines and use Deep Learning (DL) to create an isotropic fully segmented 'pseudo' 3D-cine dataset from these images.

Methods

Four DL models were trained on open-source data that performed: a) Interslice signal-correction; b) Interslice respiratory-correction; c) Super-resolution in the slice direction; and d) Segmentation of right and left atria and ventricles (RA, LA, RV, and LV), thoracic aorta (Ao) and pulmonary arteries (PA). Our method was validated in 20 patients undergoing routine cardiovascular examination, by converting prospectively acquired sagittal stacks of real-time cine images to segmented, isotropic pseudo 3D-cine data. Quantitative metrics (ventricular volumes and vessel diameters) and image quality of the DL pseudo-3D-cines were compared to reference-standard breath-hold cine and whole-heart imaging.

Results

All real-time data were successfully transformed into pseudo 3D-cines with a total offline reconstruction and post-processing time of <1min in all cases. There were no significant biases in any left ventricular (LV) or right ventricular (RV) metrics (bias ± standard deviation in ml, LV end diastolic volume (EDV): 0.7 ± 8.8, LV end systolic volume (ESV): -1.7 ± 7.1, RV EDV: 1.9 ± 12.4, RV ESV: -1.5 ± 10.7) with reasonable limits of agreement and correlation. There is also reasonable agreement for all vessel diameters, although there was a small but significant overestimation (p<0.05) of right PA (RPA) and main PA (MPA) diameter (RPA: bias = -1.0mm. MPA: bias = -1.1mm). The DL pseudo-3D-cine data were assessed to be of adequate diagnostic quality unlike the unprocessed 2D real-time data.

Conclusion

We have demonstrated the potential of creating a pseudo 3D-cine data from concatenated 2D real-time cine images using a series of DL models. Our method has short acquisition and reconstruction times with fully segmented data being available in less than one minute. Our models are trained from fully open-source datasets, allowing our technique to be easily shared with other clinical centers. The agreement with reference-standard imaging suggests that our method could help to significantly speed up CMR in clinical practice.

Read PDF

Similar papers

Open access Aug 2026

Volumetric real-time MRI for the guidance of cardiac catheterization at 0.55T.

Volumetric real-time MRI is feasible for the guidance of invasive procedures such as right-heart catheterization at 0.55T and offers flexible real-time re-slicing, volumetric 3D visualization, and the potential for improved device monitoring.

Prakash Kumar, R. Ramasawmy, A. Javed et al. · 0 citations
Review Aug 2026

Automated reconstruction of dynamic 2D fetal cardiac MRI using deep learning in late third-trimester fetuses.

INTRODUCTION Fetal cardiovascular magnetic resonance (CMR) suffers from motion corruption and cardiac gating challenges. Data-driven motion correction and gating remain dependent on manual region-of-interest (ROI) selection, limiting clinical utility through resource demands, processing time, and inter-observer variabi...

William Myers, D. Goolaub, M. Seed et al. · 0 citations
Open access Aug 2026

Accelerated Cardiac MRI Using Deep Learning Cine Imaging: Validation in Pediatric Patients both with and without Congenital Heart Disease.

BACKGROUND Conventional breath-held 2D bSSFP cine CMR requires multiple breath holds and prolonged acquisition time, posing challenges for children and patients with congenital heart disease (CHD). Deep-learning (DL)-based reconstruction enables undersampled data acquisition with rapid image completion, offering the po...

Jonathan Kochav, Jun-Jie Ma, S. Jambawalikar et al. · 0 citations
Preprint Aug 2026

SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI

The SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientat...

Arnaud Boutillon, Naomi Clarke, T. Woodgate et al. · 0 citations
Open access Aug 2026

Motion-Robust Approach for 4D Cardiac Cine Using 2D Real-Time Acquisitions and Slice-to-Volume Reconstruction.

The RT-SVR approach enables 4D cardiac cine with comparable bi-ventricular volumes, contrast, sharpness, and acquisition time compared to standard breath-hold cine while providing additional motion robustness.

Ye Tian, A. A. Joshi, Jon A. Detterich et al. · 0 citations
#diffusion models Preprint Aug 2026

Patch-Based Diffusion Reconstruction for Accelerated Cardiac Cine

Purpose: To develop and evaluate a diffusion-based reconstruction framework for highly accelerated 2D real-time (RT) cine cardiovascular magnetic resonance imaging (CMR). Methods: We trained an unconditional patch-based diffusion model and incorporated it into a reconstruction framework, termed CineDiff, using diffusio...

Xuan Lei, Philip Schniter, Juliet Varghese et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.