Skip to content
Open access

A Simple and Accurate LC–MS/MS Method for the Determination of Indobufen in Human Plasma and Its Clinical Application

Jan 2026 · Journal of Analytical Methods in Chemistry · Vol 2026 · 0 citations · 20 references
Medicine

TL;DR

In patients with moderate renal insufficiency, it is advisable to reduce the dosage to 100 mg once daily, and for patients with severe renal insufficiency, the dosage should be reduced to 1/3–1/4 of the standard dose.

Abstract

As an antithrombotic agent, indobufen is widely used in China. However, the relationship between drug concentration and therapeutic efficacy in specific patient populations remains unclear. Therefore, it is crucial to establish a method for quantifying indobufen concentrations in human plasma to guide dosage recommendations. An electrospray ionization (ESI) power supply was utilized in conjunction with multireaction monitoring (MRM) in positive ion mode. Protein precipitation was employed to extract indobufen from the plasma sample. Separation was carried out using a ChromCORE‐C18 column with a gradient elution of the mobile phase, which was composed of 0.1% formic acid in water (Solvent A) and methanol (Solvent B) at a flow rate of 0.3 mL/min. The typical standard curve equation was Y = 0.763X + 0.0986 (r = 0.9993), demonstrating a good linear relationship within the range of 0.5–30 μg/mL. All methodological outcomes complied with regulatory guidelines. In patients with moderate renal insufficiency, it is advisable to reduce the dosage to 100 mg once daily. For patients with severe renal insufficiency, the dosage should be reduced to 1/3–1/4 of the standard dose. For patients undergoing continuous renal replacement therapy (CRRT), indobufen can be gradually eliminated, and most patients do not require dose adjustment.

Read PDF

Similar papers

Open access Sep 2026

A sensitive and high-throughput LC-MS/MS method for the determination of ibuprofen: Application to a gender-comparative pharmacokinetic study

A sensitive and reliable ultra-high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of ibuprofen in plasma to investigate the pharmacokinetics of ibuprofen after oral administration of ibuprofen sustained-release capsules.

Mei-Ah Yang, Kui He, Yu-Jie Mo et al. · 0 citations
#protein folding Open access Sep 2026

Quantification of Amlexanox in Beagle Dog Plasma by LC-MS/MS and Its Application in a Comparative Pharmacokinetic Study of Conventional and Sustained-Release Tablets.

The clinical development of a sustained-release amlexanox formulation with reduced dosing frequency and improved patient compliance is supported and support the clinical development of a sustained-release amlexanox formulation with reduced dosing frequency and improved patient compliance.

Yan-Mei Yi, Wei He, Xiao-Chen Niu et al. · 0 citations
Open access Sep 2026

BIOANALYTICAL LC-MS METHOD FOR DETECTION AND QUANTIFICATION OF NIFURTIMOX IN HUMAN PLASMA

Objective: Nifurtimox is a type of nitrofuran derivative employed for treating sleeping sickness as well as Chagas disease. The aim is to develop and validate a precise and specific liquid chromatography mass spectrometric technique for the estimation of Nifurtimox in human plasma.Material and Method: Chromatographic s...

J. K. Bokam, Jagadeesh Adari, Ch Rama Naidu Gorripati et al. · 0 citations
Open access Sep 2026

LC-MS/MS Method for Simultaneous Quantification of Zolpidem, Zopiclone, and Their Metabolites in Human Urine and Its Pharmacokinetic Application.

The method's potential for retrospective urinary screening of Z-drug exposure in forensic and clinical toxicology is supported, and its potential for retrospective urinary screening of Z-drug exposure in forensic and clinical toxicology is supported.

Varsha Chauhan, Manu Sharma, Murtada Taha et al. · 0 citations
Open access Sep 2026

LC–MS/MS Method Development and Validation for Quantification of Repotrectinib in Rat Plasma and its Application to Pharmacokinetic Study

The developed LC-MS/MS method for quantifying repotrectinib in rat plasma exhibited reliability and suitability for pharmacokinetic evaluation, as evidenced by a Cmax of 52.30±0.79 ng/ml at Tmax of 5 h in rats.

Sathish Sabbani, G. Chakravarthi, N. Malothu · 0 citations
Open access Sep 2026

SIL-IS LC-MS/MS method for rapid quantification of phloroglucinol in human plasma: development, validation and application to a pharmacokinetic study.

A sensitive, rapid, and robust liquid chromatography-tandem mass spectrometry method incorporating a stable isotope-labeled internal standard incorporating phloroglucinol-13C6 was developed and validated and successfully applied to a pharmacokinetic and bioequivalence study of phloroglucinol orally disintegrating table...

Qi-Qin Sun, Xiang-Hong Li, Yun-Jie Dong et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.