Skip to content
Open access

Hardware-in-the-Loop Evaluation of Authenticated IEC 61850 Communication in Digital Substations

2026 · IEEE Access · Vol 14, pp. 117807-117828 · 0 citations · 44 references
Computer Science

TL;DR

This paper presents an IEC 61850-aligned hybrid digital twin (HDT) testbed that enables end-to-end cyber–physical evaluation of authenticated SV and GOOSE messaging in a close-to-realistic substation environment and supports systematic cybersecurity experimentation for digital substations and smart-grid cyber–physical systems.

Abstract

The increasing digitization and interconnection of substations, driven by networked intelligent electronic devices (IEDs) that function as mission-critical Industrial IoT (IIoT) endpoints, exposes time-critical IEC 61850 communications, particularly Sampled Values (SV) and Generic Object Oriented Substation Events (GOOSE), to cyber threats while also imposing stringent latency constraints on any security enhancement. This paper presents an IEC 61850-aligned hybrid digital twin (HDT) testbed that enables end-to-end cyber–physical evaluation of authenticated SV and GOOSE messaging in a close-to-realistic substation environment. The proposed HDT couples a MATLAB/Simulink power-system model (process layer) with a hardware-based communication layer comprising heterogeneous IED emulation using industrial single-board computers, Node-RED application logic, and managed Ethernet switching to reproduce station, bay, and process level interactions using SV, GOOSE, and MMS. Building on the secure SV concept, the work implements extended protocol data units to realize both Secure Sampled Values (SeSV) and Secure GOOSE (SeGOOSE) using symmetric message authentication mechanisms, specifically HMAC (SHA-256/SHA-512 variants) and AES-GMAC (128/192/256). Performance is evaluated through per-stage processing time (publisher/subscriber MAC generation and verification) and end-to-end round-trip travel time (RTTT) spanning SV publication, IED decision processing, and GOOSE actuation signaling. Results demonstrate that authenticated SV/GOOSE operation remains within IEC 61850 timing expectations under the tested configurations, with measured RTTT of approximately 1.3 ms without authentication and up to 10 ms with authentication depending on algorithm choice and platform. The testbed provides a scalable, hardware-validated methodology for quantifying the practical latency cost of IEC 61850 message authentication and supports systematic cybersecurity experimentation for digital substations and smart-grid cyber–physical systems.

Read PDF

Similar papers

Review Open access Aug 2026

IEC 61850-BASED DIGITAL SUBSTATION PROTECTION: INTEROPERABILITY, TESTING, AND LIFECYCLE MANAGEMENT FOR UTILITIES

Digital substations based on IEC 61850 are transforming utility protection, automation, and control by replacing large quantities of copper wiring with standardised communication, process-bus measurements, station-bus messaging, engineering files, and intelligent electronic devices. This paper examines IEC 61850-based...

Humayun Rafis Asop · 0 citations
Conference 2026

TROUBLESHOOTING MODBUS RTU RS-485 COMMUNICATION IN INDUSTRY 4.0 APPLICATIONS

Common communication problems in Modbus RTU networks based on the RS-485 physical layer in industrial systems within the context of Industry 4.0 are analyzed, indicating that most communication issues originate from improper implementation of the RS-485 physical layer rather than from the Modbus protocol itself.

Ana Lazarević, Marjan Urekar · 0 citations
Open access Aug 2026

Study on the Development and Field Testing of a Multi-Protocol Distribution Intelligent Switch (DIS) for Substation Communication

The design, development, and field validation of the Distribution Intelligent Switch (DIS), a unified communication gateway that consolidates multiple industrial protocols including Modbus, IEC 104, and IEC 62056 21 into a single platform using the MQTT protocol, demonstrate that it is a scalable, secure, and cost-effe...

R. Awang, J. Jalani, Khairudin Zakaria · 0 citations
Open access Aug 2026

TDT-Pipe: A Security-Aware Architecture for Trustworthy IoT Digital Twins

TT-Pipe is presented, a security-aware telemetry-to-Digital-Twin pipeline that separates message transport from update admission and indicates that the proposed validation, provenance, and controlled-admission mechanisms can be integrated into IoT Digital Twin pipelines while keeping the processing overhead limited.

Vincenzo de Angelis · 0 citations
Conference Sep 2026

Enhancing OpenFMB Security Through a Gatekeeper for Smart Microgrids

Open Field Message Bus (OpenFMB) provides interoperability, communication, and control among heterogeneous devices in microgrids. However, interoperability and message validity do not guarantee operationally safe control, since a correctly formatted, legitimate command may still violate safety constraints imposed by th...

Jhon E. García-Ortiz, K. D. Martinez-Zapata, Jaime Vergara-Tejada et al. · 0 citations
Conference Open access 2026

IoT-Enabled Electrical load monitoring using Simulink Modelling

The main contribution of this work is the development of a complete simulation-to-cloud monitoring chain that enables voltage and current signals generated from a three-phase load model to be acquired, formatted, transmitted, displayed, and remotely visualized.

Essadike Zaita, K. Boujaghama, Saadbouh Boussaoula et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.