The hybrid tomographic device demonstrated high intrasubject repeatability for epithelial thickness assessment in healthy and keratoconus eyes, supporting its technical feasibility for clinical use.
Abstract
Purpose
A novel diagnostic device combining Scheimpflug and anterior segment optical coherence tomography promises increased accuracy in corneal diagnostics. The aim of this study was to analyze the epithelial thickness measurement repeatability in healthy and keratoconus eyes and define severity-dependent thresholds.
Methods
This prospective, cross-sectional, observational, monocentric study included a total of 217 eyes of 217 subjects divided into a keratoconus group (166 eyes of 166 subjects) and a healthy control group (51 eyes of 51 subjects). Keratoconus diagnosis and stage was established using multimodal imaging. Three measurements were performed with the novel combined Scheimpflug and optical coherence tomography device (Pentacam Cornea optical coherence tomography) on the same day. Repeatability coefficients (RCs) with two-sided 95% confidence intervals (CIs) were calculated for epithelial parameters. The repeatability was compared between groups and according to keratoconus severity and crosslinking status.
Results
The median repeatability of the epithelial thickness was slightly better in the healthy group (RC = 3.3) compared with the keratoconus group (RC = 3.9; P < 0.001) when the tear film was excluded. The overall median repeatability with (RC = 3.7) and without tear film (RC = 3.8) did not differ significantly (P > 0.05). Repeatability worsened significantly in severe keratoconus stages (P < 0.01), whereas crosslinking status had only a marginal effect.
Conclusions
The hybrid tomographic device demonstrated high intrasubject repeatability for epithelial thickness assessment in healthy and keratoconus eyes, supporting its technical feasibility for clinical use. Further studies are needed to analyze the benefit of incorporating epithelium into established keratoconus scores using the hybrid system.
The new MS-39 device demonstrated moderate-to-good precision in corneal epithelial aberration measurements for FFKC, mild, moderate and total KC, and the potential of the device for early diagnosis and monitoring was still evident.
Yi-Zhou Yang, Rui Ning, Si-Heng Li et al.· Eye and Vision· 0 citations
Objectives: To assess the repeatability and reliability of anterior and posterior corneal measurements in keratoconus patients who underwent corneal allogenic intrastromal ring segment (CAIRS) implantation using a Scheimpflug-based tomography system. Methods: This prospective observational study included 42 eyes: 20 ke...
Uğur Tunç, Dilan Çolak, Burcu Yakut et al.· Beyoglu Eye Journal· 0 citations
Purpose: To compare ocular biometric measurements and postoperative refractive prediction accuracy between swept-source optical coherence tomography (Anterion®) and low-coherence reflectometry (Lenstar LS900®) using five intraocular lens (IOL) power calculation formulas.Methods: This retrospective study included 72 pat...
Dasom An, G. Bae, S. Shin· Journal of the Korean Ophtha...· 0 citations
PURPOSE
To evaluate the effect of rigid gas-permeable (RGP) contact lens correction on macular optical coherence tomography (OCT) measurements in patients with keratoconus and determine whether retinal thickness differences persist after correction of corneal irregularity.
METHODS
This observational case-control stud...
N. Elkady, M. Salama, M. Elshazly et al.· Contact lens & anterior eye...· 0 citations
PURPOSE
To evaluate the repeatability of anterior segment parameters measured with a novel swept source optical coherence tomography (SS-OCT) instrument, and to compare these anterior segment parameters with those measured with the CASIA2.
METHODS
This prospective case series study included 119 eyes from 119 particip...
Zheng-Yuan Qu, Yan Huo, Rui-Si Xie et al.· Photodiagnosis and Photodyna...· 0 citations