Skip to content
Open access

Fault Line Selection Strategy for Distribution Networks Based on Dynamic and Accurate Measurement of Zero-Sequence Current—A Data–Model Hybrid-Driven Method

Aug 2026 · Processes · Vol 14, pp. 2656 · 0 citations · 37 references

Abstract

The measurement accuracy issue of zero-sequence current transformers (CTs) has long been a critical factor restricting the accuracy of fault line selection in distribution networks. Although existing research methods are relatively mature in theory, their on-site application is limited by the measurement precision of zero-sequence CTs. To address this problem, this paper proposes a fault line selection strategy for distribution networks based on dynamic and accurate measurement of zero-sequence current. Firstly, from the data perspective, this paper analyzes the fault characteristics of various electrical quantities in different operation stages of distribution networks. Combined with system characteristics, an accurate measurement method for zero-sequence current amplitude is subsequently put forward. Afterwards, a distribution network fault line selection algorithm optimized by an attention mechanism-based multi-scale convolutional neural network is constructed. Finally, verification results based on the IEEE standard test system demonstrate that the proposed method enhances the capabilities of feature extraction and side information aggregation, realizes efficient and accurate localization of faulty lines, and exhibits strong robustness under noisy conditions.

Read PDF

Similar papers

Conference Open access Aug 2026

Automatic switching control of transformer simulated fault resistance network based on high-voltage integrated signal enhancement algorithm

Strong noise in high-voltage transformer environments can easily overwhelm weak fault signals during the switching control of simulated fault resistance networks. This interference hinders the accurate identification of fault types and levels, ultimately compromising the stability and accuracy of the switching process....

Wei-Ping Wu, Tie-Gang Yang · 0 citations
Open access 2026

A Data-Mechanism Fusion Method for Distribution Network Fault Diagnosis Based on Digital Twin

: Accurate fault diagnosis in distribution networks is essential for ensuring reliability and reducing outage time, particularly as power systems undergo digital transformation. Existing digital twin-based methods struggle to deeply integrate data-driven adaptability with physics-based interpretability, which limits th...

Hao-Nan Xie, Duan-Jiao Li, Bo Jiang et al. · 0 citations
Open access Sep 2026

Design of a comprehensive protection algorithm for fault detection, classification, and location in high voltage direct current transmission lines connected to wind farms based on local terminal measurements

With the increasing adoption of bipolar high-voltage direct-current (HVDC) transmission lines for wind farm integration, the development of fast, accurate, and communication-independent protection schemes has become a critical technical requirement. This paper proposes a comprehensive protection algorithm within an int...

Mahyar Abasi, Vahid Davatgaran, Morteza Azizi · 0 citations
Conference Aug 2026

Simulation Research on Fault Location in Small Current Grounding Systems of Distribution Networks Based on Feature Fusion

This paper focuses on the research of fault location under different operating conditions and noise interference. Due to the limitations of single features, this paper proposes a multi-feature fusion fault location method based on Extreme Learning Machine (ELM) to improve the effectiveness and accuracy of single-phase...

Tong-Yang Li, Lin-Jing Hu, Wen-Chen Hu · 0 citations
Open access Sep 2026

Mechanism–Data Dual-Driven Outage Identification Framework for Distribution Networks with High Penetration of Inverter-Based Distributed Generation

INTRODUCTION: High penetration of inverter-based distributed generators (IBDGs) changes power-flow patterns and fault transients in distribution networks, reducing the effectiveness of conventional outage identification. Under the adopted low-voltage ride-through control model, IBDG fault currents are limited to 1.2–1....

Ning Liu, Xiao-Peng Zhang, Xu-Dong Wang et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.