This work introduces ELECTRIC (Evidential Learning-Enhanced CT Reconstruction via Iterative Correction), a physics-guided Bayesian formulation that provides an evidential neural network and an error-predictive epistemic-uncertainty surrogate, and demonstrates the complete ELECTRIC closed-loop pipeline.
Abstract
Here we introduce ELECTRIC (Evidential Learning-Enhanced CT Reconstruction via Iterative Correction), a physics-guided Bayesian formulation. An evidential neural network provides an image proposal and an error-predictive epistemic-uncertainty surrogate. The latter is converted into an adaptive precision field and inserted into a Poisson-weighted MAP update. The resulting image-evidence-precision-reconstruction loop treats prior confidence as a learned state variable of iterative reconstruction. In addition to the formulation and theoretical analysis, we report two simulation studies on image slices from the AAPM Mayo Clinic Low-Dose CT dataset: a mechanism-validation pilot using transparent surrogate estimators, and a feasibility study in which a trained Normal-Inverse-Gamma evidential network drives the full closed loop. On held-out patients, the learned prior mean reduces reconstruction error by roughly 70 percent relative to filtered back-projection, the learned epistemic uncertainty is error-predictive and supports selective trust, and the physics-guided update restores measurement consistency while the adaptive-precision reconstruction matches or exceeds a validation-tuned fixed prior and remains markedly more robust to prior-strength misspecification. Together these results demonstrate the complete ELECTRIC closed-loop pipeline, while identifying formal uncertainty calibration and joint training as the principal directions for future work.
Normal-inverse-gamma (NIG) regression is not uniquely identifiable from its marginal Student-t likelihood: the likelihood determines three combinations of four NIG parameters and is constant along a one-dimensional fiber. We identify that fiber using independent physical measurement. As an initial embodiment, a reconst...
Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps.
Medical image reconstruction began with an exact mathematical result. In 1917, Radon showed how to recover a function from its line integrals, providing the mathematical basis for computed tomography, positron emission tomography, and single-photon emission computed tomography. This review follows the development of re...
Nicholas E. Protonotarios, Sotiris Messinis, G. Kastis et al.· Mathematics· 0 citations
Normal-inverse-gamma (NIG) regression is not identifiable from its marginal Student-t likelihood: three combinations of four NIG parameters are determined, leaving one degree of freedom. We introduce PEEL-DDPM, a physics-enabled evidential learning framework for denoising diffusion probabilistic models. A measurement-c...
Reconstructing multidimensional vector fields from path-integrated projection data is a fundamental challenge in high-energy-density physics, particularly when experimental sources exhibit spectral broadening and shot-to-shot jitter. We present a physics-guided deep-learning framework that addresses this ill-posed inve...
Catherine Jao, Chiung-Yin Chang, Kun-Han Lee et al.· APL Machine Learning· 0 citations