A Green Analytical Stability Indicating RP HPLC Method for Determination of Related Impurities in Istradefylline Dosage Forms. Robustness Study by Quality by Design Approach

Aug 2026 · Saudi Journal of Medical and Pharmaceutical Sciences · 0 citations

TL;DR

A novel, stability-indicating, Quality by Design (QbD)-based and eco-friendly RP-HPLC method was developed and validated for the determination of Istradefylline and its related impurities in tablet dosage forms, demonstrating excellent specificity.

Abstract

Istradefylline, a selective adenosine A2A receptor antagonist used as an add-on therapy to levodopa therapy for Parkinson’s disease, requires reliable impurity profiling to ensure pharmaceutical quality and safety. In this study, a novel, stability-indicating, Quality by Design (QbD)-based and eco-friendly RP-HPLC method was developed and validated for the determination of Istradefylline and its related impurities in tablet dosage forms. Method robustness was systematically evaluated using a three-level, two-factor factorial design. Chromatographic separation was achieved on an XBridge C18 column (250 × 4.6 mm, 5 µm) using 0.01M ammonium formate buffer (pH 4.0) and acetonitrile at a flow rate of 0.8mL min⁻¹, with detection at 280 and 360nm. The method demonstrated excellent specificity, effectively separating Istradefylline from its impurities (IST-4, IST-5, IST-CIS, IST-10, and IST-40) without interference from excipients and degradation products. Linearity was established over the concentration range of 0.200–4.000µgmL⁻¹ (R² > 0.999), while accuracy, precision, and sensitivity met ICH acceptance criteria. Forced degradation studies confirmed the stability-indicating capability of the method. The method also complies with Green Analytical Chemistry principles through reduced solvent consumption and efficient chromatographic performance. Validation results demonstrated that the method is robust, reliable, and suitable for routine quality control, impurity profiling, and stability assessment of Istradefylline tablet formulations.

Read PDF

Similar papers

Open access Aug 2026

QbD-Assisted RP-HPLC Method Development and Validation for the Quantification of Sotagliflozin With LC-MS/MS Characterization of Its Degradation Products and Greenness Assessment Using AGREE and MoGAPI.

An AQbD-based approach was employed to develop and validate a reliable, stability-indicating RP-HPLC method for quantifying sotagliflozin in API and tablet dosage forms, demonstrating good linearity, precision, accuracy, robustness, and sensitivity with low LOD and LOQ values.

Ankita Gupta, Akash Sharma, G. Devi et al. · 0 citations
Open access 2026

To develop and validate the stability indicating method for Empagliflozin and Linagliptin using HPLC method

The developed RP HPLC method is simple, rapid, selective, accurate, economical, and can be used for routine pharmaceutical quality control, stability testing and analysis of combined Linagliptin and Empagliflozin formulation.

M. B. Sufi, Vaishnavi Daldale, Irshad Ahmed · 0 citations
Open access Sep 2026

Method Development, Validation and Estimation of Single Synthetic Drug Tafamidis by RP-HPLC and Green Analysis in API Form and Pharmaceutical Dosage Form

For the quantitative determination of Tafamidis in bulk and pharmaceutical dosage forms, a straightforward, accurate, precise, and environmentally friendly reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated. To achieve optimal chromatographic performance, several stationa...

H. K. Qureshi, Hurria Fatima, Amtul Zaman et al. · 0 citations
Open access Sep 2026

AI-Assisted Stability-Indicating RP - HPLC Method Development and Validation for the Quantitative Estimation of Tafamidis in Bulk Drug and Pharmaceutical Dosage Forms

A stability-indicating reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the quantitative estimation of Tafamidis in bulk drug and pharmaceutical dosage forms. Chromatographic separation was achieved using a Phenomenex Gemini ODS C18 column (250 × 4.6 mm, 5 µm) with...

Badikela Rama Krishna, Challamalla Pavani, B. Vasudeva et al. · 0 citations
Sep 2026

Analytical Quality by Design (AQbD) Driven Development of a Robust Stability-Indicating RP-HPLC Method for the Precision Estimation of Dapagliflozin and Vildagliptin in Combined Fixed-Dose Tablets

A simple, accurate, precise, and stability-indicating RP-HPLC method was developed and validated for the simultaneous estimation of Dapagliflozin (DAPA) and Vildagliptin (VILDA) in a combined tablet dosage form using a Quality by Design approach. Method development was carried out systematically by identifying importan...

Rajesh Patil Tabassum I. Hangad · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.