Aug 2026· Applied Sciences· Vol 16, pp. 7995· 0 citations· 18 references
Abstract
The modernization of legacy industrial machines is a major challenge in intelligent automation, particularly when critical assets must be upgraded without replacing high-value mechanical and hydraulic infrastructure. This paper presents an industrial case study on the intelligent PLC-based retrofit of an obsolete Neyrpic Digipid speed governor installed in a Kaplan turbine. The proposed solution replaces a closed, vendor-dependent controller with an open Siemens ET 200SP architecture programmed in TIA Portal, integrating existing sensors, hydraulic actuators, redundant speed acquisition, sequential state-machine control, and a digital distributor–runner blade Cam Curve. A key technical contribution is the diagnosis and mitigation of hydraulic hunting in the distributor position loop. The instability was traced to the interaction between integral control action and the intrinsic integrating behavior of the hydraulic actuator, leading to the adoption of a proportional-only position tracking strategy. The system was validated through Factory Acceptance Tests (FATs) and Site Acceptance Tests (SATs), including signal verification, startup, synchronization, load acceptance and emergency load rejection. Quantitative results demonstrate that during initial commissioning of the new PLC-based PI position loop, the LVDT position error reached 41.59% peak-to-peak, with 351.2 servo-valve reversals per minute. Disabling the integral action reduced the peak-to-peak position error to below 1.5% and eliminated steady-state valve reversals under the tested operating conditions. Separately, the historical 0.966 V oscillation detected in the legacy analog-input chain was resolved during the retrofit. During no-load startup, the unit reached 97% of nominal speed in 49.4 s, with a maximum overshoot of 2.3% and a speed tracking standard deviation of 1.1%. The complete operational cycle was successfully validated under real industrial conditions, including a near-nominal load-rejection test (approximately 2.25 MW), during which the measured speed peaked at 126.4% of nominal speed and the shutdown sequence was completed without protection-system malfunction. The results show that open PLC-based retrofits can improve maintainability, diagnostics and operational reliability in safety-critical industrial machines, while establishing a foundation for future SCADA integration and condition-based maintenance.
This study presents the design and experimental evaluation of a laboratory-scale High-Pressure Acid Leaching (HPAL) autoclave integrating a Siemens S7-1200 programmable logic controller (PLC), Modbus RTU industrial communication, an Internet of Things (IoT) gateway, and a cloud-based Web-SCADA platform for real-time mo...
Afandy Moh, Yulianti Malik, Abdul Haris Mubarak et al.· Journal of Renewable Energy...· 0 citations
To address issues such as loose structure, low integration, and reliance on imports in existing marine electro-hydraulic actuators, this paper presents an integrated compact electro-hydraulic actuation device. The device integrates the drive unit, connection block, hydraulic actuation unit, and feedback signal box into...
Jian-Gang Yan· Yanbu Journal of Engineering...· 0 citations
To improve fuel-supply continuity and coordinated protection in civil aircraft fuel systems, this paper presents an integrated control architecture for fuel boost pumps based on a Frequency Regulation Controller (FRC). Cockpit commands, fuel-computer references, sensor feedback, and hardware protection signals are coor...
Ding-Qi Deng, Cheng-Xu Sun, Yuan-Mei Wu et al.· Journal of Physics, Conferen...· 0 citations
This study aims to improve the stability and performance of control of the moving crosshead in the main hydraulic directional control valve of a 10,000-tf forging press manufactured by Ural Heavy Machinery Plant (UZTM, Russia). The press is used to produce rings of various profiles and materials as part of the ring-rol...
K. Litsin, S. Baskov, D. Morkovnik· iPolytech Journal· 0 citations
The safe and stable operation of pumped storage hydropower (PSH) plants is heavily reliant on the correctness of their Supervisory Control and Data Acquisition (SCADA) systems. Conventional testing methods often fall short in validating the complex, system-wide control logic under comprehensive operational scenarios. T...
Chen Zhang, Ting Liang, Yi-Fan Li et al.· PLoS ONE· 0 citations