Skip to content
Open access

A Rapid and Sensitive LC–MS/MS Method for Quantification of NDSRI in Melatonin Drug Product via Controlled In Situ Formation

Aug 2026 · Biomedical chromotography · Vol 40 · 0 citations · 30 references
Medicine

TL;DR

A liquid chromatography–tandem mass spectrometry method was developed and validated for quantifying N‐Nitroso melatonin, and the scavenger eliminated false positives by suppressing in situ nitrosamine formation, ensuring data integrity.

Abstract

ABSTRACT Nitrosamine drug substance–related impurities (NDSRIs) pose a significant safety risk due to their mutagenic and carcinogenic potential, prompting strict regulatory oversight under ICH M7. The propensity for in situ formation of NDSRIs during analytical procedures, particularly in active pharmaceutical ingredients containing reactive amines, emphasizes the need for highly accurate and scrupulously validated methodologies. Melatonin, containing a vulnerable amine, was chosen as a model drug product. A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for quantifying N‐Nitroso melatonin. To prevent in situ formation, a scavenger was incorporated during sample preparation. Validation followed regulatory standards, assessing specificity, linearity, accuracy, precision, sensitivity, and robustness. The method showed excellent linearity (1.8–22.5 ng/mL, R 2 = 0.9983), sensitivity with LOD of 0.9 ng/mL and LOQ of 1.8 ng/mL, and accuracy with recoveries between 85.3% and 95.9%. Precision was confirmed with %RSD below 2%, whereas robustness testing demonstrated consistent performance under varied conditions. Crucially, the scavenger eliminated false positives by suppressing in situ nitrosamine formation, ensuring data integrity. This validated approach strengthens analytical accuracy and provides a transferable framework for monitoring NDSRIs in other drug products containing reactive amines, supporting regulatory compliance and safeguarding patient health.

Read PDF

Similar papers

Open access Sep 2026

A NOVEL STABILITY-INDICATING UHPLC–MS/MS METHOD FOR QUANTITATIVE DETERMINATION OF BREXPIPRAZOLE IN BULK DRUG SUBSTANCE: DEVELOPMENT, VALIDATION, AND FORCED DEGRADATION STUDIES

Background: Brexpiprazole is an atypical antipsychotic drug used to treat schizophrenia and agitation induced by Alzheimer's disease. Aim: The present study aimed to develop and validate a simple, rapid, sensitive, and stability-indicating UHPLC MS/MS method for measuring Brexpiprazole by using a dilute-and-shoot sampl...

Priyadharshini, Balachandar K, Sampangi Bharath et al. · 0 citations
Aug 2026

Validated LC-MS/MS method for ultra-trace determination of N-nitroso-desmethyl sumatriptan in sumatriptan succinate injection.

A rapid and highly sensitive LC-MS/MS method was developed and validated for the determination of the nitrosamine drug substance-related impurity N-nitroso-desmethyl sumatriptan (NNDS) in sumatriptan succinate injection. Separation was achieved on an Inertsil ODS-3 column using gradient elution with 0.1% formic acid in...

Srivathsa Degekar G., Niranjan Patra · 0 citations
Open access Sep 2026

Development of a Sensitive Analytical Method for the Determination of Sulforaphane in Vegetables by Automated Online In-Tube SPME/LC–MS/MS

Sulforaphane (SFN), an isothiocyanate abundant in cruciferous vegetables, possesses well-documented anticancer, antioxidant, and anti-inflammatory properties, and has attracted interest as a dietary chemopreventive agent. However, sensitive and fully automated methods for its quantification in foods remain limited. In...

Keita Saito, Tomoaki Okamura, Hiroyuki Kataoka · 0 citations
Open access Aug 2026

QbD-Assisted RP-HPLC Method Development and Validation for the Quantification of Sotagliflozin With LC-MS/MS Characterization of Its Degradation Products and Greenness Assessment Using AGREE and MoGAPI.

An AQbD-based approach was employed to develop and validate a reliable, stability-indicating RP-HPLC method for quantifying sotagliflozin in API and tablet dosage forms, demonstrating good linearity, precision, accuracy, robustness, and sensitivity with low LOD and LOQ values.

Ankita Gupta, Akash Sharma, G. Devi et al. · 0 citations
Sep 2026

Development of an MSPE-UHPLC-MS/MS method for bisphenols and alkylphenols in personal care products: a pilot study and preliminary safety assessment in China.

As daily essentials for skin protection and cosmetic enhancement, personal care products (PCPs) are used extensively worldwide. Due to their direct and prolonged contact with the skin, any hazardous ingredients they contain warrant serious attention. Although bisphenols (BPs) and alkylphenols (APs) are of growing conce...

Shu-Yan Sun, Ya-Lei Dong, Ming Jin et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.