A highly-sensitive and selective LC-MS/MS platform for quantitative determination of diosgenin in mice plasma with comprehensive bioanalytical validation and pharmacokinetic study.
Overall, this robust and highly sensitive LC-MS/MS method is reliable for trace-level quantification and demonstrated its applicability in pharmacokinetic, bioavailability, and formulation studies of diosgenin.
Abstract
A robust and highly sensitive LC-MS/MS method was developed and validated for the quantification of diosgenin in mice plasma in accordance with ICH M10 guidelines. Chromatographic separation was achieved using Kinetex C8 column (50 x 2.1 mm, 5 µm) with 0.1% formic acid in distilled water and methanol as mobile phase at a flow rate of 0.6 mL/min, and the run time was 17 min. Detection was performed in positive ESI+ mode using MRM at m/z 415.10 → 271.20, employing sarsasapogenin as the internal standard. Protein precipitation yielded efficient extraction with minimal matrix interference. The method exhibited excellent linearity over 3.125-1000 ng/mL (r2 = 0.996) with an LLOQ of 3.125 ng/mL. The accuracy during within-day and between-day evaluations ranged from 91.7% to 110.99%, and precision (%CV) remained below 5.14%. Dilution integrity indicated that the analyte can be reliably quantified in biological samples up to 24,000 ng/mL. The stability studies confirmed that the analyte was stable under various conditions. Further, this validated method was applied for pharmacokinetic studies in female mice via oral (10mg/kg) and intramuscular (5mg/kg) administration. Overall, the method is reliable for trace-level quantification and demonstrated its applicability in pharmacokinetic, bioavailability, and formulation studies of diosgenin.
A sensitive and reliable ultra-high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of ibuprofen in plasma to investigate the pharmacokinetics of ibuprofen after oral administration of ibuprofen sustained-release capsules.
Mei-Ah Yang, Kui He, Yu-Jie Mo et al.· Acta Chromatographica· 0 citations
The findings regarding accuracy, specificity, sensitivity, matrix effect, recovery and stability findings of Lurbinectedin in plasma samples for the established method highlight its significance in bioequivalence and pharmacokinetic studies.
P. Sankar, Naresh Panigrahi· International Journal of App...· 0 citations
A rapid isocratic LC-MS/MS method for quantifying busulfan in human plasma was developed and validated. Plasma samples were processed by protein precipitation with acetonitrile using busulfan-d8 as the internal standard. Separation was performed on a Kinetex C18 column (2.1 × 50 mm, 5 µm; Phenomenex) with isocratic elu...
A sensitive and validated liquid chromatography-tandem mass spectrometry method was developed for the simultaneous quantification of the anti-COVID-19 agents molnupiravir, its active metabolite N-hydroxycytidine (NHC), and baricitinib in human plasma, and met the acceptance criteria.
Fatma H. Ghazy, Ramzia I. El-Bagary, Samar H. Fahim et al.· Bioanalysis· 0 citations
Amlexanox, a 5H-benzopyranopyridine derivative with emerging therapeutic potential in metabolic and inflammatory diseases, lacks a validated analytical method for pharmacokinetic studies in beagle dogs. A sensitive LC-MS/MS method was developed and validated for amlexanox in beagle dog plasma according to ICH M10 guide...