Skip to content

An Adaptive Pilot Protection for Wind Farm Transmission Line Employing Multiscale Morphological Gradient

2026 · IEEE Canadian Journal of Electrical and Computer Engineering · Vol 49, pp. 605-616 · 0 citations · 30 references

Abstract

The complex fault-currents and prominent harmonic components of doubly-fed induction generators (DFIGs) pose significant sensitivity and mal-operation risks for traditional pilot protection on long-distance transmission lines. To address these issues, this article proposes a novel adaptive time-domain pilot protection scheme based on multiscale morphological gradients. This method uses morphological gradient with multiscale structural elements for robust fault-current characterization, extracting transient fault current features at both ends of the line, balancing computational efficiency with detailed waveform preservation. Fault detection is achieved through kurtosis of morphological gradients within a sliding window, complemented by an adaptive weighted sum of energy differences criterion to distinguish internal from external faults. The proposed method was validated using a wind farm transmission line model in power systems computer aided design (PSCAD)/electromagnetic transients, including DC (EMTDC). Extensive PSCAD/EMTDC simulations demonstrate that the proposed scheme achieves ultrafast fault detection within 1.5 ms and requires a minimal computational load of only 11 core operations (COps) per data point. Furthermore, by extracting and transmitting only scalar feature values via an adaptive alignment mechanism, it completely eliminates the reliance on strict time synchronization. The energy index maintains a distinct selective margin even under extreme boundary conditions, proving its superior practical reliability for wind farm export lines.

View source

Similar papers

Conference Aug 2026

An AI-integrated adaptive pilot protection strategy using hierarchical Euclidean distance for transmission lines

Simulation results in PSCAD/EMTDC demonstrate that the proposed method significantly outperforms traditional differential protection in sensitivity and reliability, effectively mitigating maloperation risks under highimpedance faults and weak-infeed conditions, offering a viable software upgrade path for existing infra...

Ying Zou, Luyun Zhang, Chenyang Wang et al. · 0 citations
Open access Sep 2026

Design of a comprehensive protection algorithm for fault detection, classification, and location in high voltage direct current transmission lines connected to wind farms based on local terminal measurements

With the increasing adoption of bipolar high-voltage direct-current (HVDC) transmission lines for wind farm integration, the development of fast, accurate, and communication-independent protection schemes has become a critical technical requirement. This paper proposes a comprehensive protection algorithm within an int...

Mahyar Abasi, Vahid Davatgaran, Morteza Azizi · 0 citations
Open access Sep 2026

Artificial neural network-enhanced solid-state DC breaker for ultra-fast protection in LVDC microgrids

Low voltage direct current (LVDC) microgrids are increasingly adopted due to their efficiency in integrating distributed energy resources (DERs) and DC loads without multiple conversion stages. However, the presence of high amplitude fault currents and the vulnerability of electronic devices pose significant challenges...

Eswaraiah Giddalur, Askani Jaya Laxmi · 0 citations
Open access 2017

Frequency Regulation of offshore Wind Power Generation using VSC-HVDC Converter

This paper deals with the development of a Mat lab-simulink model of a new proposed scheme for grid connected off shore wind farm (OWF) and marine current farm (MCF) on a VSC-HVDC. The purpose of this simulation Model to getting better damping enhancement and voltage control. An equivalent Doubly fed Induction Generato...

Choppara Harsha Vardhan, K. V. Narayana · 0 citations
Conference Aug 2026

Distance Protection Method for AC Transmission Lines Considering VSC Impact

The integration of Voltage Source Converter (VSC) based flexible DC systems leads to the maloperation of traditional distance protection, threatening grid stability. This paper reveals how converter current-limiting and decoupling controls cause fault current phase shifts under phase-to-phase faults, forcing the operat...

Ming-Dong Dang, K. Dong, Hua-Yu Zheng · 0 citations
Open access Sep 2026

Voltage–Current Curve-Based Line Protection for Renewable Energy Systems with Grid-Forming Inverters

The increasing penetration of inverter-based renewable energy resources is reshaping transmission-line fault characteristics and weakening protection criteria designed for synchronous-generator-dominated grids. This paper proposes an internal-fault identification scheme based on voltage–current coupling characteristic...

Long-Fei Ren, Xiao He, Wei-Zhen Li et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.