An intelligent fault and lightning detection algorithm based on S transform and Residual Network with hybrid attention mechanism (RWHAM) that exhibits excellent generalization ability when the parameters of VSC-MTDC grids change.
Abstract
To address the existing challenges in fault detection for voltage source converter-based multi-terminal DC (VSC-MTDC) grids, this paper proposes an intelligent fault and lightning detection algorithm based on S transform and Residual Network with hybrid attention mechanism (RWHAM).The DC line double-ended initial current traveling waves (ICTWs) are first converted into time-frequency matrices by performing S transform and then visualized as a two-dimensional image. The image effectively characterizes the time-frequency features of ICTWs under different fault and lightning conditions, making it easier to extract critical features for the models. Next, the RWHAM model is constructed and the images are fed into the model to detect internal and external faults and lightning interference. The weight of the key information in the image is increased by hybrid attention mechanism, which in turn improves the fault detection ability of the RWHAM model. Extensive simulations involving 21,620 distinct cases on PSCAD/EMTDC validate the algorithm's high accuracy and rapid response across different types of faults and lightning interference. Furthermore, it exhibits excellent generalization ability when the parameters of VSC-MTDC grids change.
In recent years, high penetrations of inverter-based resources are posing significant challenges to the medium-voltage networks, in which protection schemes based on high fault currents and unidirectional power flow may not perform as expected. This paper proposes a dynamic fault-detection and relay-coordination scheme...
Muhammad Abdul Rauf, Munira Batool, I. Madni· Energies· 0 citations
The increasing penetration of inverter-based renewable energy resources is reshaping transmission-line fault characteristics and weakening protection criteria designed for synchronous-generator-dominated grids. This paper proposes an internal-fault identification scheme based on voltage–current coupling characteristic...
Long-Fei Ren, Xiao He, Wei-Zhen Li et al.· Electronics· 0 citations
The complex fault-currents and prominent harmonic components of doubly-fed induction generators (DFIGs) pose significant sensitivity and mal-operation risks for traditional pilot protection on long-distance transmission lines. To address these issues, this article proposes a novel adaptive time-domain pilot protection...
An Li, Ying-Jun Zhuo, Si-Yu Lu et al.· IEEE Canadian Journal of Ele...· 0 citations
With the increasing adoption of bipolar high-voltage direct-current (HVDC) transmission lines for wind farm integration, the development of fast, accurate, and communication-independent protection schemes has become a critical technical requirement. This paper proposes a comprehensive protection algorithm within an int...
Mahyar Abasi, Vahid Davatgaran, Morteza Azizi· PLoS ONE· 0 citations
The increasing operational complexity and fault vulnerability of Nigeria’s electrical distribution
networks demand intelligent systems capable of rapid fault detection, accurate localization, and
efficient isolation. This study develops an intelligent fault detection and location framework for
the Ayepe 34-bus Niger...
G. Ajenikoko· INTERNATIONAL JOURNAL OF APP...· 0 citations
Protection of electrical power systems is the major issue in power industry and for the protection of these electric power systems, current distance relays are widely applied due to their inherent simplicity, excellent sensitivity on internal faults and high stability on external faults. This work represented the probl...
A. Rajak, Preeti Rajput, M. Choubey· International journal of res...· 0 citations