Experimental studies of microclimatic conditions in the cabins of electric locomotive drivers to improve workplace safety systems and devices and increase safe railway operation
Jul 2026· Вестник Ростовского государственного университета путей сообщения· pp. 113-123· 0 citations· 3 references
Abstract
The article presents the results of a statistical analysis of the microclimate parameters (temperature, the environmental heat load index – EHL-index) in the cabins of electric locomotive drivers of the EP1M, 2ES5K and VL-80 series. The study is based on data of a special assessment of electric locomotive crews’ working conditions carried out at different times of the year. The methods of descriptive statistics and data visualization revealed that the empirical distributions of the studied parameters differ significantly from the normal one and represent a mixture of several components, each of which corresponds to a certain class of working conditions and is close to the normal distribution. It has been established that the effect of a heating microclimate poses a greater risk to locomotive crew members compared to the cooling one. The results of the work serve as the basis for the development and validation of mathematical models of heat and mass transfer, as well as for the design of microclimate normalization systems and devices in drivers' cabins to ensure workplace safety and safe railway operation of rolling stock.
The temperature parameters of the external environ-ment influence such performance indicators of a rotary snow blower as energy efficiency and productivity, which also largely determine the quality of cleaning. The article describes a hardware and software system designed to collect and process data on the operation of...
D. A. Aleshkov, I. Teterina· Nauchno-tekhnicheskiy vestni...· 0 citations
It is necessary to ensure a high-quality microclimate of the main building of a thermal power plant (TPP) for efficiency of technological process and compliance with the requirements of current regulatory documents in the field of industrial hygiene. In this regard, the development of an adequate mathematical model of...
V. Bukhmirov, I. Svetushkov, D. Dolinin et al.· Vestnik IGEU· 0 citations
The power units of mainline diesel locomotives are one of the primary technical systems ensuring the continuous and safe operation of railway transport. The operational reliability of these power units is directly linked to the timely assessment of their technical condition, the detection of malfunctions in their initi...
Shohijakhon Kudratov, O. Khamidov, Bakhodir Gayratov et al.· Вестник транспорта - Transpo...· 0 citations
The paper discusses the development and improvement of rational types of enclosing structures for wooden buildings, taking into account the coupled heat and mass transfer processes occurring in them and environmental safety. A comparative analysis of typical structures reduced to a unified standard thermal resistance i...
Sergey V. Fedosov, V. Fedoseev, P. Razgovorov et al.· Smart composite in construct...· 0 citations
In hot climates, the ambient air temperature can reach 45 °C and more, which leads to heating of the windings of power transformers above the permissible values and, accordingly, to a reduction in their relative service life. The purpose of the study is to determine the values of relative service life and the factors a...
A. Alzakkar, N. Mestnikov, Y. Samofalov· 2026 International Russian A...· 0 citations
The relevance of monitoring the force-and-power parameters of strip rolling on hot and cold rolling mills is emphasized. This task arises when expanding the product mix, modernizing equipment, and developing new rolling programs. Several known methods for calculating force-and-power parameters are noted, the calculatio...