Aug 2026· Journal of Functional Biomaterials· Vol 17, pp. 385· 0 citations· 35 references
Medicine
TL;DR
Under the evaluated conditions, the 3D-printed holder exhibited less positional variability than the conventional alginate-based holder.
Abstract
This exploratory proof-of-concept study aimed to develop and preliminarily evaluate a 3D-printed holder designed for reuse in cone beam computed tomography (CBCT) in dental research, particularly for comparative studies requiring pre- and post-intervention tooth assessment. The holder was designed using computer-aided design software and fabricated from polylactic acid using 3D printing. A conventional alginate-based holder was used for comparison. The comparison therefore concerned two complete positioning systems with different geometries and modes of adaptation to the CBCT headrest. The two positioning devices were independently placed by two operators with different levels of experience, and all CBCT scans were acquired by the same operator. The procedure was repeated after a 5-day interval. Root canal morphology was assessed using volumetric and surface measurements, as well as voxel counts. The independently segmented canal models were qualitatively displayed together in their native coordinate space to visualize positional consistency between acquisitions. Paired analyses showed substantially lower positional deviations with the 3D-printed holder than with the conventional holder in all four acquisition comparisons (Holm-adjusted p < 0.001). Mean deviations ranged from 0.126 to 0.172 mm for the 3D-printed holder and from 3.626 to 8.318 mm for the conventional holder. Morphometric parameters derived from 3D analysis remained identical across all acquisitions, regardless of operator, time point, or positioning method. Qualitative 3D analysis showed near-complete overlap for the 3D-printed holder and clear spatial discrepancies for the conventional holder. Under the evaluated conditions, the 3D-printed holder exhibited less positional variability than the conventional alginate-based holder.
The type of scan body did not significantly affect the accuracy of digital impressions for bone-level implants and the mean and standard deviation of Root Mean Square Eror (RMSE) were calculated.
A. Fathi, Ehsan Ghasemi, Seyyed Parsa Tabatabaei et al.· Journal of Oral Implantology· 0 citations
Introduction: To compare the accuracy of implant placement on mandibular models fabricated from different materials using a single digitally designed surgical guide, and to identify which model provided the highest precision and cost-effectiveness for research and training applications.
Materials and Methods: Nine ide...
Raniah Isam Muwafaq al Khashali, Dr. Bayad Jaza Mahmood· Journal of craniomaxillofaci...· 0 citations
Objectives: To evaluate the three-dimensional adaptation of prefabricated Bio-Root inlays fabricated from impressions of simulated immature permanent root canals using four techniques: direct intraoral scanning (A), a light-body rubber impression digitized with an intraoral scanner (B), cone-beam computed tomography (C...
The auxiliary device developed in this study allows for consistent detector angle maintenance and fixation during hip joint axiolateral projection, thereby improving reproducibility and ease of examination, and suggests its potential usefulness for achieving more accurate imaging in clinical settings.
D. Hong, Yeongcheol Joo, Eunhye Kim· Radiation· 0 citations
Background. Modern dental practice is going through a period of active digital transformation especially in dental implantology area. Surgical planning accurancy has become particularly important due to increasing demands for the quality and durability of prosthetic appliances. Traditional methods based on gypsum cast...
L. A. Ziulkina, Artem E. Kriushin, O. Ilyunina et al.· University proceedings Volga...· 0 citations
Evaluated occlusal devices fabricated using digital techniques showed clinical outcomes and participant satisfaction similar to those produced using hybrid workflows, and a significant material‑based difference was found.
Ayşegül Yıldıran, Helin Su Akyol Kurtça, Bilge Gokcen Rohlig· The Journal of prosthetic de...· 0 citations