In scanning microscopy, drift causes the specimen to be sampled at positions displaced from the nominal probe positions. This displacement alters the spatial assignment of the recorded signals and biases quantitative measurements across two-dimensional imaging, channel-resolved spectroscopic mapping, and scan-position-resolved diffraction analysis. Here, we extend orthogonal-scan drift correction from 2D images to spectrum images and diffraction datasets. We demonstrate how to recover probe positions using either differently oriented multidimensional scans or structural reference images. The recovered positions are used either to resample the multidimensional data onto a regular grid or to assign each recorded signal to its corrected coordinate. Our method combines affine and non-rigid correction, requires no prior structural model, and is implemented as open-source, GPU-accelerated software that reduces processing times by two to three orders of magnitude, enabling routine and automated drift correction for quantitative multidimensional microscopy.
Scanning-probe x-ray tomography is useful for imaging nanoscale structures of a sample. The image resolution, which can reach down to 10 nm by the increased brightness and coherence of the x-ray optics, however, is highly susceptible to experimental error. Failure to address these errors can lead to a smeared image and...
Xiang Huang, P. Brahmbhatt, Chang Meng et al.· 6 citations
Four-dimensional scanning transmission electron microscopy (4D-STEM) records a two-dimensional diffraction pattern at each electron-probe position, yielding spatially resolved reciprocal-space information but large, heterogeneous data volumes. Here we describe 4D-ImageNet, a collection of 174,000 diffraction patterns c...
Yu-Yan Guan, Hao-Ran Zhang, Zian Mao et al.· 0 citations
Scanning probe microscopy (SPM) has become a mainstay of materials science, condensed matter physics, nanotechnology, biology, and semiconductor metrology. An SPM image, however, is acquired sequentially as the probe traverses the surface under closed-loop feedback while thermal drift, feedback dynamics, tip state, mec...
Surya Prakash Reddy, Sergei V. Kalinin· 0 citations
Atomic-scale phase imaging is central to resolving defects, interfaces, and weakly scattering atoms that govern the behavior of nanoscale materials. Electron ptychography delivers sub-{\aa}ngstr\"om phase sensitivity but remains an offline technique, because its iterative reconstruction is computationally expensive and...
H. Yue, Charles B. Chen, C.-N. Hsiao et al.· 0 citations
In a point-scanning microscope, detection through a pinhole improves resolution and replacing the pinhole with a detector array provides redundant encoding of the object spectrum, enabling correction of nonidealities in the imaging system or further resolution improvements, for instance. Here, we show that the mathemat...
Two-Photon microscopy (TPM) is an intravital imaging technique with deep tissue penetration, high three-dimensional resolution and low photobleaching. However, imaging speeds have traditionally been limited because images are generated by point scanning. Recently, Spectro-Temporal Laser Imaging by Diffractive Excitatio...
C. Stock, Gregory Berg, Matthea Thielking et al.· Frontiers in Photonics· 0 citations