Jul 2026· Journal of Medical Imaging· Vol 13 6, pp.
062206
· 0 citations
Medicine
TL;DR
This work provides an openly released resource consisting of tracked real motion and pregenerated synthetic motion, along with a pretrained variational autoencoder (VAE) to generate larger ground-truth datasets, intended to support reproducible development, benchmarking, and comparison of head motion estimation methods in medical imaging modalities.
Abstract
Purpose
Rigid head motion during interventional C-arm cone-beam CT (CBCT) is a major source of image degradation. Learning-based motion estimation requires realistic training data, but ground-truth motion is scarce, limiting direct validation of compensation trajectories. We address this gap with an open resource consisting of tracked real motion and pregenerated synthetic motion, along with a pretrained variational autoencoder (VAE) to generate larger ground-truth datasets.
Approach
Using stereo optical tracking, we recorded rigid 6-DoF head motion trajectories from 25 volunteers lying head-first supine on an examination table, resembling a clinical setting. After data preprocessing, we trained a VAE on 120 sequences of 10 s at 30 Hz. Motion is represented in patient-centered coordinates to support transformation to arbitrary scan geometries. Similarity between measured and generated data is assessed via distributional distances, correlation metrics, low-dimensional embeddings, and a posthoc analysis of the learned latent space.
Results
Evaluated based on 120 generated sequences, the trained VAE is capable of producing diverse 6-DoF trajectories that preserve real-world data correlation structure. Distributional and frequency-domain metrics, along with t-SNE embeddings, show overlap between real and synthetic samples without evidence of mode collapse or training data replication.
Conclusions
This work provides an openly released resource comprising measured trajectories, a synthetic dataset, and pretrained VAE weights together with full training and evaluation code, combining rigid 6-DoF head motion measured in a realistic C-arm setting with a retrainable generative model. It is intended to support reproducible development, benchmarking, and comparison of head motion estimation methods in medical imaging modalities.
TLCE-morph, a Tri-Path Lie Convolution Encoder-based learning framework for deformable respiratory motion correction in thoracic PET, achieves the most favorable overall quantitative performance and shows more consistent local structural recovery in representative motion-sensitive regions.
Hui Zhou, Long-Xi He, Si-Yu Wang et al.· Frontiers of Physics· 0 citations
The benefits of combining prospective and retrospective motion correction, where the Scout Accelerated Motion Estimation and Reduction (SAMER) technique is utilized for on-the-fly motion estimation with field-of-view (FoV) updates along with retrospective correction of potential residual motion, are demonstrated.
Hongli Fan, B. Clifford, Michael Koenig et al.· Magnetic Resonance in Medici...· 0 citations
OBJECTIVE
Supervised synthetic computed tomography (sCT) generation from cone-beam CT (CBCT) requires spatially registered training pairs, yet perfect registration between separately acquired scans is unattainable. This registration bias propagates into trained models and corrupts intensity-based evaluation, so higher...
L. Zimmermann, Michael Rauter, Martin Buschmann et al.· Physics in Medicine and Biol...· 0 citations
This non-patient-specific CNN predicts static volumes and full 4D respiratory motion models from a single free-breathing scan, without a respiratory surrogate or projection binning, reducing motion artifacts while adding motion-modeling capability.
Ivo Herzig, P. Paysan, Daniel Barco et al.· 0 citations
Results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.
M. Safari, Shan-Song Wang, Zach Eidex et al.· IEEE Transactions on Medical...· 0 citations
While image quality metrics suggested superior overall correction with MOS, an in vivo framework provided a more detailed characterization of in vivo performance differences, Notably, the framework detected a subtle improvement in FatNav performance with neck masking, an effect uncaptured by conventional image quality...
Zakaria Zariry, Frank Lamberton, Robert Frost et al.· NMR in Biomedicine· 0 citations