Measured and synthetic rigid head motion datasets via generative model for motion simulation and compensation in medical imaging.

Jul 2026 · Journal of Medical Imaging · Vol 13 6, pp. 062206 · 0 citations
Medicine

TL;DR

This work provides an openly released resource consisting of tracked real motion and pregenerated synthetic motion, along with a pretrained variational autoencoder (VAE) to generate larger ground-truth datasets, intended to support reproducible development, benchmarking, and comparison of head motion estimation methods in medical imaging modalities.

Abstract

Purpose Rigid head motion during interventional C-arm cone-beam CT (CBCT) is a major source of image degradation. Learning-based motion estimation requires realistic training data, but ground-truth motion is scarce, limiting direct validation of compensation trajectories. We address this gap with an open resource consisting of tracked real motion and pregenerated synthetic motion, along with a pretrained variational autoencoder (VAE) to generate larger ground-truth datasets. Approach Using stereo optical tracking, we recorded rigid 6-DoF head motion trajectories from 25 volunteers lying head-first supine on an examination table, resembling a clinical setting. After data preprocessing, we trained a VAE on 120 sequences of 10 s at 30 Hz. Motion is represented in patient-centered coordinates to support transformation to arbitrary scan geometries. Similarity between measured and generated data is assessed via distributional distances, correlation metrics, low-dimensional embeddings, and a posthoc analysis of the learned latent space. Results Evaluated based on 120 generated sequences, the trained VAE is capable of producing diverse 6-DoF trajectories that preserve real-world data correlation structure. Distributional and frequency-domain metrics, along with t-SNE embeddings, show overlap between real and synthetic samples without evidence of mode collapse or training data replication. Conclusions This work provides an openly released resource comprising measured trajectories, a synthetic dataset, and pretrained VAE weights together with full training and evaluation code, combining rigid 6-DoF head motion measured in a realistic C-arm setting with a retrainable generative model. It is intended to support reproducible development, benchmarking, and comparison of head motion estimation methods in medical imaging modalities.

Read PDF

Similar papers

Open access Aug 2026

SO(3)-based and structure-guided deformable registration for respiratory motion correction in thoracic PET

TLCE-morph, a Tri-Path Lie Convolution Encoder-based learning framework for deformable respiratory motion correction in thoracic PET, achieves the most favorable overall quantitative performance and shows more consistent local structural recovery in representative motion-sensitive regions.

Hui Zhou, Long-Xi He, Si-Yu Wang et al. · 0 citations
Jul 2026

Combining Prospective and Retrospective Motion Correction, Using the Scout Accelerated Motion Estimation and Reduction (SAMER) Framework, for Rapid and Motion-Robust 2D TSE Imaging.

The benefits of combining prospective and retrospective motion correction, where the Scout Accelerated Motion Estimation and Reduction (SAMER) technique is utilized for on-the-fly motion estimation with field-of-view (FoV) updates along with retrospective correction of potential residual motion, are demonstrated.

Hongli Fan, B. Clifford, Michael Koenig et al. · 0 citations
Open access Aug 2026

Eliminating Registration Bias in Synthetic CT Generation using a physics-based simulation framework for pelvic anatomy.

OBJECTIVE Supervised synthetic computed tomography (sCT) generation from cone-beam CT (CBCT) requires spatially registered training pairs, yet perfect registration between separately acquired scans is unattainable. This registration bias propagates into trained models and corrupts intensity-based evaluation, so higher...

L. Zimmermann, Michael Rauter, Martin Buschmann et al. · 0 citations
Open access Aug 2026

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction.

Results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.

M. Safari, Shan-Song Wang, Zach Eidex et al. · 0 citations
Open access Aug 2026

Intra‐MRI Head Motion Tracking and Correction: A Quantitative In Vivo Evaluation Framework

While image quality metrics suggested superior overall correction with MOS, an in vivo framework provided a more detailed characterization of in vivo performance differences, Notably, the framework detected a subtle improvement in FatNav performance with neck masking, an effect uncaptured by conventional image quality...

Zakaria Zariry, Frank Lamberton, Robert Frost et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.