Multicenter Comparison of Computerized Insulin Sensitivity Coefficient and Paper-Based Intravenous Insulin Protocols.

Jul 2026 · Journal of Diabetes Science and Technology · pp. 19322968261462502 · 0 citations · 23 references
Medicine

TL;DR

A computerized ISC-based insulin infusion protocol resulted in more blood glucose values in target range and lower rates of hypoglycemia compared with paper-based protocols.

Abstract

INTRODUCTION Computerized intravenous (IV) insulin infusion calculators may offer a safe and efficacious means of achieving glycemic control. Historically, our health system utilized various paper-based IV insulin infusion protocols but transitioned to a computerized insulin infusion calculator protocol based on the insulin sensitivity coefficient (ISC) in 2024. The objective of this study was to compare the safety and efficacy of the computerized ISC-based insulin infusion calculator protocol with previous protocols.

Methods

This was a pre-post intervention analysis of critically ill adult patients initiated on a paper-based insulin infusion across 13 institutions from March 2023 to May 2023 for pre-analysis and patients on a computerized, ISC-based insulin infusion from November 2024 to December 2024 for post-analysis. The primary outcome was the percentage of blood glucose levels within target range (80-180 mg/dL). Secondary outcomes included rates of hyperglycemia (>200 mg/dL), severe hyperglycemia (>250 mg/dL), hypoglycemia (<70 mg/dL), and severe hypoglycemia (<54 mg/dL).

Results

In total, 207 and 237 patients were included in the pre- and post-intervention groups, respectively. For the primary outcome, 4610 of 6313 (73%) and 6163 of 7870 (78.3%) of blood glucose values were in range in the pre- and post-intervention groups, respectively (P < .01). There was no difference in severe hypoglycemia (0.2% vs 0.1%, P = .24), but rates of hyperglycemia (16.6% vs 12.6%, P < .01), severe hyperglycemia (5.7% vs 4.0%, P < .01), and hypoglycemia (0.7% vs 0.2%, P < .01) were higher in the pre-intervention group.

Conclusions

A computerized ISC-based insulin infusion protocol resulted in more blood glucose values in target range and lower rates of hypoglycemia compared with paper-based protocols.

Read PDF

Similar papers

Open access Aug 2026

Real-World Outcomes of Automated Insulin Delivery Use in Hospitalized Adults With Diabetes.

Continuation of insulin pumps was associated with improvement in hyperglycemia without increased hypoglycemia risk and with shorter LOS in the hospital and standardized institutional policies may help expand safe continuation of AID during hospitalizations.

Kathleen R Ruddiman, J. Evans, Joseph A. Aloi et al. · 0 citations
Review Aug 2026

Kontinuierliche Glukosemessung und automatisierte Insulindosierungssysteme im klinischen Alltag

A practice-oriented evaluation of the indications, clinical benefits, and safety of modern diabetes technologies and suggests that technologies should be offered according to individual needs, abilities, preferences, and life circumstances and implemented early, including at the time of diagnosis.

A. Mathew, D. Führer · 0 citations
Open access Jul 2026

Long-term Performance of a Dynamic Clinical Decision Support System for Intravenous Insulin Therapy: A Retrospective Cohort Study in Patients With and Without Diabetes.

Use of Glucopilot, an electronic medical record-integrated adaptive insulin dosing software, was associated with timely attainment of euglycemia and sustained glycemic control with a median of 0% time in hypoglycemia in real-world practice.

Benjamin Lalani, Ruth Penno, Curt Bay et al. · 0 citations
Open access Jul 2026

Effect of Active Insulin Time and Glycemic Targets on Automatic Correction Bolus Delivery.

Active insulin time is a key modifiable parameter influencing AB delivery and glycemic outcomes, and shorter AIT settings were associated with increased AB administration and improved TIR, whereas glucose target settings had no significant impact on these outcomes.

Giuseppe Papa, R. Cannarella, C. Gusmano et al. · 0 citations
Open access Jul 2026

Improvement in insulin injection timing and glucometrics using a connected insulin cap: the Insulclock v2.0® prospective study

Objectives Matching insulin injection timing with meals to optimize postprandial glucose excursions is a daily challenge for individuals with diabetes on a multiple daily injection (MDI) regimen. We aimed to analyze the impact of using a connected insulin pen cap (CIPC) on insulin injection timing and glycemic control....

F. Gómez-Peralta, J. M. Borrachero, Estefanía Santos et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.