Skip to content
Open access

Enhanced selectivity in alpelisib quantification in human plasma: a validated LC-MS/MS method with deuterated internal standard

Jul 2026 · Journal of Applied Pharmaceutical Research · Vol 14, pp. 247-256 · 0 citations

TL;DR

A reliable, sensitive, and selective liquid chromatography-tandem mass spectrometry method suitable for high-throughput pharmacokinetic studies and therapeutic drug monitoring of ALB in human plasma is developed and validated.

Abstract

Background: To enhance efficacy and manage dose-limiting toxicities such as hyperglycemia, therapeutic drug monitoring of alpelisib (ALB), a phosphatidylinositol 3-kinase alpha (PI3Kα) inhibitor used in advanced breast cancer, is essential. This study aimed to develop and validate a selective, sensitive, and high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of ALB in human plasma to support pharmacokinetic studies and therapeutic drug monitoring. Methodology: Alpelisib-D3 was used as a deuterated internal standard (IS). Analytes were extracted from 50 µL of plasma by liquid-liquid extraction using n-hexane and methyl tert-butyl ether (20:80, v/v). Chromatographic separation was performed on an X-Terra RP8 column using an isocratic mobile phase of 5 mM ammonium acetate buffer (pH 5.00) and acetonitrile (10:90, v/v) at 0.4 mL/min. Detection was carried out in positive electrospray ionization mode using multiple reaction monitoring of m/z 442.15→141.07 for ALB and m/z 445.36→144.05 for the IS. Validation included linearity, precision, accuracy, recovery, matrix effect, carryover, dilution integrity, and stability. Results and discussion: The method was linear over 50.0–10,000 ng/mL. Intra- and inter-day precision (CV%) was <4.2%, and accuracy ranged from 94.5% to 106.2%. Mean extraction recovery exceeded 90%, with no significant matrix effects. Carryover, stability, and dilution integrity also met acceptance criteria. Conclusion: A reliable, sensitive, and selective LC-MS/MS method was successfully developed and validated. The method is suitable for high-throughput pharmacokinetic studies and therapeutic drug monitoring of ALB in human plasma.

Read PDF

Similar papers

Open access Sep 2026

Development and Validation of a UPLC–MS/MS Method for Simultaneous Quantification of Ensartinib and Its Major Metabolite M465 in Rat Plasma and Application to Pharmacokinetic Studies

A sensitive, reliable, and rapid UPLC–MS/MS method was developed and validated for the simultaneous determination of ensartinib and M465 in rat plasma and applied to a rat pharmacokinetic study and provides useful analytical support for further preclinical investigations of ensartinib and its major metabolite.

Shi-Qi Jiang, Yan Chen, Lu Cao et al. · 0 citations
Aug 2026

Simultaneous determination of bosutinib and its metabolite in rat plasma by UPLC-MS/MS: Development, validation and application to pharmacokinetic and metabolic stability studies.

In vivo pharmacokinetic studies confirmed that the UPLC-MS/MS method could be successfully used for the analysis of bosutinib after oral administration of 50 mg/kg in rats, and provides a potential reference for the clinical investigation of bosutinib.

Pei-Qi Wang, Yan Chen, Jun Wu et al. · 1 citation
Open access Aug 2026

A validated bioanalytical LC-MS/MS method for the simultaneous determination of molnupiravir, N-hydroxycytidine, and baricitinib in human plasma.

A sensitive and validated liquid chromatography-tandem mass spectrometry method was developed for the simultaneous quantification of the anti-COVID-19 agents molnupiravir, its active metabolite N-hydroxycytidine (NHC), and baricitinib in human plasma, and met the acceptance criteria.

Fatma H. Ghazy, Ramzia I. El-Bagary, Samar H. Fahim et al. · 0 citations
Aug 2026

Development and validation of an HPLC-MS/MS method for the quantification of Aficamten in human plasma and urine and application to a clinical pharmacokinetic study.

An innovative, rapid, and highly sensitive HPLC-MS/MS approach for quantifying aficamten concentrations in human plasma and urine is established and critical validation parameters including matrix effects, extraction recovery, carryover, and stability were assessed.

Xiao-Fei Wu, Aijing Liu, Adrienne Griffith et al. · 0 citations
Jul 2026

A highly-sensitive and selective LC-MS/MS platform for quantitative determination of diosgenin in mice plasma with comprehensive bioanalytical validation and pharmacokinetic study.

Overall, this robust and highly sensitive LC-MS/MS method is reliable for trace-level quantification and demonstrated its applicability in pharmacokinetic, bioavailability, and formulation studies of diosgenin.

Hrishikesh Khude, Rohan Pai, Pravin K. Shende · 1 citation
#protein folding Aug 2026

Development and ICH M10-compliant validation of an LC-MS/MS method for quantification of atirmociclib in mouse plasma and its application to preclinical pharmacokinetic studies.

The first validated liquid chromatography tandem mass spectrometry (LC-MS/MS) bioanalytical method for the quantification of atirmociclib in mouse plasma is reported, validated in compliance with international council for harmonisation-M10 (ICH-M10) guidelines.

Ashwani Gaur, U. Patel, Ashutosh Gavali et al. · 0 citations