Skip to content
Open access

Quantitative Risk Assessment Models for Extinguishing and Controlling Hydrogen Fires and Explosions Across the Hydrogen Energy Cycle

2026 · International journal of research and scientific innovation · Vol 13, pp. 3236-3247 · 0 citations

Abstract

Hydrogen is widely regarded as a clean energy carrier for decarbonising mobility and stationary power, yet its wide flammability range, low ignition energy and high flame speed make fire and explosion the governing hazards across the supply chain. This study develops and applies a quantitative risk assessment (QRA) framework to estimate, evaluate and control fire and explosion risks for seven representative objects spanning the hydrogen energy cycle: a solar hydrogen production plant, a liquid-hydrogen (LH2) depot, a fuelling station, an on-board vehicle tank, a fuel-cell combined heat and power (CHP) unit, a road tanker and a gaseous-hydrogen (GH2) pipeline. Accident scenarios were identified using HAZOP and FMEA. Event frequencies were derived from a combined fault-tree and event-tree analysis (FTA/ETA) with lognormal basic-event data propagated through 10,000 Monte-Carlo trials, while road-transport and pipeline frequencies were obtained from historical accident statistics. Physical consequences—dispersion, jet fire, pool fire, fireball, flash fire and vapour-cloud explosion—were simulated with PHAST Professional v6.4 (DNV) and converted to fatality levels using thermal-radiation and overpressure probit relations. Individual and societal (F-N) risks were benchmarked against the ALARP/ALARA acceptance criteria and against an equivalent liquefied-petroleum-gas (LPG) study. Continuous releases dominated loss of containment (~94%), with tank overpressure as the leading initiator (~50%); fires accounted for ~60% of outcomes and explosions ~5%. The overall societal risk of the hydrogen cycle was 8.5 × 10−3/year, dominated by the fuelling station (39%) and the on-board vehicle tank (35%). Although individual risks for hydrogen storage exceeded those of LPG, the maximum effect distances and societal risks were consistently smaller, indicating that hydrogen poses a lower public risk than LPG of comparable tank size. The framework identifies critical weak points and prioritised risk-reduction measures for the safe deployment of hydrogen infrastructure

Read PDF

Similar papers

Open access Sep 2026

Fire Suppression Simulation and Risk Assessment for a Lithium-Ion Battery Energy Storage Station

Lithium-ion battery energy storage stations are being rapidly deployed for peak regulation, renewable energy integration, and emergency power supply in power systems. Their fire risk is governed by interacting factors, including cell thermal runaway, equipment failure, operating environment, personnel behavior, managem...

Jun-Wei Shi, Ziyan Zhang, Zi-Ming Xu · 0 citations
Sep 2026

The hidden hazard of green shipping: risk transfer in maritime decarbonisation

Experts predominantly evaluate maritime decarbonisation using carbon metrics, yet the shift from heavy fuel oil to alternative fuels could systematically transfer environmental and operational risks across hazard categories, life-cycle stages, and affected communities. This paper addresses the analytical gap in multidi...

Ashraf Dawar, Yang Bai, Muhammad Waqar Khan et al. · 0 citations
Conference Open access Aug 2026

Research on the fire risk of aviation kerosene and fire prevention measures for oil depots

To assess the fire risk of aviation kerosene, its flash point, explosion limit, sustained combustion characteristics, and heat release rate were tested experimentally, while its vapor composition was analyzed using gas chromatography-mass spectrometry (GC-MS). The results indicate that, compared to typical flammable li...

Hai-Hao Cui, Jia-Jie Xu · 0 citations
Open access Aug 2026

Comparative Probabilistic Risk Assessment of Alternative Marine Fuels in Traffic Separation Schemes Using Monte Carlo Simulation

The transition towards low-carbon shipping has accelerated the adoption of alternative marine fuels such as ammonia, hydrogen, methanol and liquefied natural gas (LNG). Although these fuels reduce greenhouse gas emissions, they introduce new operational hazards related to toxicity, flammability, cryogenic storage and e...

Candela Maceiras Tajes, Manuel Vázquez Neira, F. J. Pérez-Castelo et al. · 0 citations
Conference Open access Aug 2026

Thermal safety risks and eco-friendly energy technologies for underground lithium-ion electric vehicles

The global growth of electric vehicles (EVs) has made underground garages high-risk for lithium-ion battery thermal incidents. Using PyroSim, a numerical model of a typical underground garage was set, and multiple cases were simulated to monitor temperature, CO concentration, and visibility. Results show pronounced cou...

Wan-Ru Lan, Hao-Peng Lei · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.