Aug 2026· Engineering Journal· Vol 30, pp. 19· 0 citations
Abstract
Standalone micro-hydro power plants commonly regulate excess generation through electronic load controllers, which dissipate surplus energy in ballast loads. This study evaluates a dual-inverter variable-frequency-drive framework that prioritizes domestic demand and directs the remaining DC-link power to a motor-pump system. The controller applies 6/4 kW hysteresis and a 0.7 kW/s pump-power ramp limit. A 24-hour energy-management analysis was combined with a short-duration switched-inverter assessment of DC-link and load-side power quality. For a 30kW generator, the system served 423.69 of 424.00 kWh/day of domestic demand and supplied 181.08 kWh/day to the pump drive, recovering 95.95% of the available DC-side surplus. Relative to a conventional electronic load controller, useful end-use utilization increased from 65.75% to 84.66%. The regulated output had a mean phase voltage of 225.85 V, a mean frequency of 49.982 Hz, a maximum frequency deviation of 0.0346 Hz, and a voltage total harmonic distortion of 3.996%. The results indicate that the proposed configuration can reduce dissipative surplus handling while maintaining domestic energy service and acceptable load-side power quality.
The integration of Thermostatically Controlled Loads (TCLs) into the active power regulation framework of power systems provides a variety of benefits and multifarious uses. The TCLs specifically heating, ventilation, and air-conditioning (HVAC) systems constitutes the majority of the power demands in modern power syst...
Syed Ali Mashal, Shaeer Jan, Muhammad Haris· International Journal of Inn...· 0 citations
Converter-dominated microgrids (MGs), an emerging class of converter-dominated power systems (CDPS), feature extensive converter-interfaced distributed energy resources (DERs) and power-electronic loads such as variable-frequency drives (VFDs). A representative example is the Natural Energy Laboratory of Hawaii Authori...
Zakaria Afshar, Saeed Sepasi, Josep M. Guerrero· IEEE Open Access Journal of...· 0 citations
Highlights What are the main findings? Low-output-voltage THD is demonstrated under both linear and nonlinear load conditions. DC-side battery/impedance network regulation and AC-side voltage control are achieved within a single-stage power-conversion structure. What is the implication of the main finding? The proposed...
Seyfettin Vadi, Meral Özarslan Yatak· Italian National Conference...· 0 citations
This paper presents a community energy management system (CEMS) for coordinating flexible residential devices, including electric vehicles (EVs), heat pumps, photovoltaic (PV) systems, and batteries. The framework focuses on demand-side flexibility and voltage support for the local distribution system operator. Device-...
With the increasing penetration of wind power in modern power systems, primary frequency regulation (PFR) capability has become a mandatory requirement for grid integration. Drawing on the PFR mechanisms of conventional thermal power plants, this paper proposes control strategies for wind farms, specifically including...
Ling Liu· International Journal of Met...· 0 citations
Direct-drive wave power generation systems based on permanent magnet linear generators (PMLGs) produce fluctuating electromagnetic power under irregular wave excitation, which may affect DC-bus voltage stability and load-side power quality. To smooth the fluctuating output power, this paper develops an empirical mode d...
Zheng-Yuan Zhu, Yu-Da Sheng, Min-Shuo Chen et al.· Journal of Marine Science an...· 0 citations