2026· IEEE Transactions on Instrumentation and Measurement· Vol 75, pp. 5019414-5019414· 0 citations· 40 references
Abstract
This study presents a curve-based pixel-wise calibration method for microelectromechanical system (MEMS) mirror-based fringe projection profilometry (FPP) systems. The MEMS mirror, working at its resonant mode, exhibits dynamic deformation that bends the projected laser fringes into quadratic curves rather than ideal straight lines, leading to a certain reconstruction error. A polynomial phase–height mapping model with bidirectional phase coupling is derived by combining the pinhole camera model and rigid body transformations between coordinate systems. A pixel-wise calibration strategy with hierarchical fitting is then adopted to estimate model parameters. The MEMS mirror-based FPP system was built with a resonant frequency of 1.15 kHz and a maximum deflection angle of ±15°. The curve model achieves a mean calibration error of 0.0575 mm and a standard deviation of 0.0151 mm, outperforming the linear model (0.0612 and 0.0322 mm). Reconstruction mean error is reduced by 1.1 %–27.9 % and standard deviation is reduced by 0.6 %–27.4 % over existing methods, with planar targets showing greater improvement. A human sculpture reconstruction clearly recovers fine surface details, including 0.8 mm-wide strings. Drawing inspiration from the geometric distortion characteristics of MEMS mirrors, this work provides an effective solution for improving reconstruction accuracy in compact and high-speed MEMS-based FPP systems.
Highlights A calibration method based on grooved curvature templates is developed for MCF-FBG shape sensors. The effective rotation angle used for sinusoidal fitting is corrected jointly for the four FBG responses. A 20 cm four-core MCF containing 200 femtosecond-laser-inscribed FBGs in 50 sensor planes is demonstrated...
Yi Jiang, M. Angelmahr, Ahmad Abdalwareth et al.· Italian National Conference...· 0 citations
Vortex beams with unique helical phase structures and orbital angular momentum (OAM) features have become promising candidates for high-precision optical metrology. However, most vortex-beam interferometers demonstrated to date are restricted to single-parameter measurement, hindering their broader application in multi...
Yuan-He Shi, Yun-Ting Wang, Ke-Di Wu et al.· IEEE Transactions on Instrum...· 0 citations
Understanding insect locomotion is important for both biological studies and bioinspired robotics. Although multiaxis force plates have been developed to measure ground reaction forces (GRFs) in terrestrial insects, the simultaneous measurement of six-axis forces and moments remains challenging. In this study, we propo...
Accurate and efficient tuning of small-radius-of-curvature (RoC) bendable mirrors remains challenging under variable beamline conditions, while conventional analytical tuning is often inadequate. To address this problem, this study presents the design, modeling, and multi-method optimization of a small-RoC bendable mir...
Bao-Ning Sun, Zhi-Xiang Wen, Qing-Hao Zhu et al.· Journal of Synchrotron Radia...· 0 citations
To meet the high-precision calibration requirements of optical full-field strain measurement systems for standard deformation inputs, this paper proposes a deformation measurement method for a multifunctional calibration component based on laser interferometric measurement combined with synchronous angle measurement us...
Hai-Rong Chen, Peng Chen, Le-Yuan Peng et al.· Global Intelligent Industry...· 0 citations
Opposing working surfaces of a dual-sided specular component cannot be observed in a common field of view, which complicates simultaneous measurement of their surface forms and spatial relationship in a unified frame. To address this issue, a near-optical-coaxial phase measuring deflectometry (PMD) method based on a pr...
Yu Zhao, Ming-Xin Qi, Yu-Bo Ni et al.· Optics Express· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.