A single radiation hard pixel detector for proton dosimetry, imaging, energy resolution and beam monitoring

Oct 2026 · 0 citations · 41 references
Physics

TL;DR

GaN pixel detectors are presented as a scalable and radiation-hard platform, enabling dosimetry, beam monitoring and energy verification in one device, establishing GaN pixel detectors as a scalable and radiation-hard platform, enabling dosimetry, beam monitoring and energy verification in one device.

Abstract

Proton therapy enables highly conformal tumour irradiation by exploiting the Bragg peak. Clinical precision relies on detector systems that provide linearity, spatial resolution, radiation hardness, and, for ultra-high-dose-rate (FLASH) therapy, high dynamic range with sufficient temporal response. No compact all-in-one solution currently fulfils all these requirements. Here, we present pixelated gallium nitride (GaN) arrays as a multifunctional platform. These detectors exhibit high linearity (proton currents from 70 to 1700 pA cm-2) and signal uniformity below 2% across 128 pixels. To probe GaN radiation hardness, we applied cumulative doses up to 6.7 MGy at energies from 25 MeV down to the Bragg-peak regime. Locally deposited dose dictates long-term signal loss, yet devices preserve linearity and spatial response. We demonstrate 0.25 mm effective spatial resolution, validated against radiochromic film. Proton radiography resolves fine tissue structures, with the dose extrapolated to 7 mGy per 1 ms frame in a prospective single-shot configuration. Energy-dependent responses match GATE/Geant4 simulations, and wedge measurements enable Bragg-peak tracking with an energy resolution below 10 keV in an optimised geometry. Real-time ms-scale beam monitoring enables live dose verification.These results establish GaN pixel detectors as a scalable and radiation-hard platform, enabling dosimetry, beam monitoring and energy verification in one device.

View source

Similar papers

Conference Open access Sep 2026

A scintillator-based approach to spatial and temporal dosimetry in UHDR electron irradiation

The clinical translation of FLASH-radiotherapy remains limited by the lack of accurate dosimetry at ultra-high dose rates (UHDR), as many conventional detectors exhibit strong dose-rate dependence or insufficient temporal resolution. Scintillation detectors, with their fast response and high spatial capability, represe...

F. Hörberger, K. Petersson, Carola Villa et al. · 0 citations
Conference Open access Sep 2026

Monte-Carlo simulations of Cherenkov Fluence for FLASH radiotherapy dosimetry

FLASH radiotherapy uses ultra-high dose rate (UHDR) beams to reduce normal tissue toxicity while maintaining tumor control. However, accurate dosimetry for UHDR beams is challenging due to saturation effects and temporal limitations of conventional detectors. Optical methods using Cherenkov radiation represent a promis...

Thibault Bernelin, A. Lalonde, L. Archambault · 0 citations
Oct 2026

Investigating the behavior of hydrogenated amorphous silicon under UHDR proton beam

Radiation-based therapies are crucial treatments in the fight against malignant cancers. Ultra-high dose rate (UHDR) proton therapy promises a higher radiobiological advantage and increased effectiveness in targeting tumor cells while sparing healthy cells by providing the total dose in a short time at a rate higher th...

K. El Achi, A. Warnier, A. Khalilzadeh et al. · 0 citations
Open access Oct 2026

easyPET.3D measurement of positron emitter maps in proton-irradiated PMMA phantoms

This work presents the first experimental evaluation of the easyPET, a compact and cost-effective preclinical positron emission tomography scanner, as a potential tool for quality control assessment and validate the potential of easyPET.3D as a promising, accessible solution for proton range verification.

A. C. M. Magalhães, P. Correia, M. Grossmann et al. · 0 citations
Sep 2026

Study of three-dimensional dose distribution measurement of ultra-high dose rate electron beam

Objective. FLASH radiotherapy which employs an ultra-high dose rate (UHDR) ( >40 Gy s −1), effectively protects normal tissues and organs while maintaining robust tumor control. However, it also presents serious challenges for quality assurance (QA). Currently, dosimeters face various limitations under FLASH radiothera...

Wei Zhang, Chang Cheng, Rong-Hu Mao et al. · 0 citations

Physics in Medicine & Biology

Jing-Hui Wang, Ming-Qing Wang, Heng Wang et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.