B-015 Precision Compatibility - Clinical Comparative Study of Lipid Panel Reagents on Six Mainstream Instruments

Oct 2026 · Clinical Chemistry · Vol 72 · 0 citations

TL;DR

The established multi-dimensional lipid dissociation technology effectively degrades lipid particles, mitigates chylomicron interference, and eliminates matrix effects in lipemic samples, overcoming the long-standing challenge of lipemia interference.

Abstract

Accurate lipid testing is essential for managing dyslipidemia but faces two key challenges: matrix interference from lipemic samples, which biases results and compromises comparability, and inter-platform variability due to differing methods and reagents. To address these issues, this study establishes a multi-dimensional synergistic lipid dissociation technology. It effectively neutralizes sample-specific interferences while ensuring consistent performance across six major instrument platforms. This study utilized the Zybio biochemical lipid reagent kit, covering six core lipid parameters (HDL-C, LDL-C, CHOL, TG, APOA1, APOB), and performed simultaneous measurements on five instruments: Zybio EXC200, EXC400, and EXC2000 biochemical analyzers; the third-party Hitachi LABOSPECT 006 biochemical analyzer; and the Beckman AU5800 biochemical analyzer. The results from these five testing systems were concurrently compared with those obtained from the Roche Cobas 701 biochemical analyzer with its matching detection kits. A total of 660 samples were measured synchronously across all six platforms. For all six lipid panel analytes, excellent clinical correlation was observed across the five testing systems, with correlation coefficients (r)?>0.995?and overall concordance rates?>98%, demonstrating no significant inter-system differences. Among the 660 simultaneously tested samples (480 normal samples and 180 lipemic samples), none of the six lipid parameters exhibited clinically significant discrepant results. All parameters showed high clinical agreement with the Roche reference system, with correlation coefficients (r)?>0.992 and overall concordance rates?>95%, demonstrating exceptional inter-system consistency and clinical reliability. This study confirms that the established multi-dimensional lipid dissociation technology effectively degrades lipid particles, mitigates chylomicron interference, and eliminates matrix effects in lipemic samples. All six lipid analytes demonstrated strong correlation with the Roche reference system, overcoming the long-standing challenge of lipemia interference. Additionally, supported by Zybio’s comprehensive reference system and international traceability framework, lipid panel reagents exhibited excellent cross-platform consistency across six testing platforms, validating their stability and clinical accuracy for cardiovascular disease prevention.

View source

Similar papers

Oct 2026

A-038 Validation of a Specialized Lipids Panel LDT for Serum Analysis Using the Roche Cobas 8000 c702 Platform

A Specialized Lipids Panel LDT on the Roche Cobas 8000 c702 that integrates precipitation-based HDL-C with ultracentrifugation-derived LDL-C provides a more accurate alternative to estimation formulas and direct homogenous assays, particularly in complex lipid profiles.

Solomon Taboh, S. Narla, Nadia Ayala-Lopez et al. · 0 citations
Oct 2026

A-043 Validation of the ImPress upper arm blood collection device for standard and advanced lipid panel markers

Cardiovascular disease continues to be the universal leading cause of death. Preventative screening and monitoring plays an important role in mitigating risk, however, socially disadvantaged communities frequently face major challenges in receiving appropriate care. The evolution of cardiovascular risk assessment...

Anissa R. Naranjo, Carlos Torres, C. Carter et al. · 0 citations
Open access Oct 2026

BEST-06 | OPTIMIZING LABORATORY MONITORING OF EFANESOCTOCOG ALFA: IMPACT OF APTT REAGENTS AND CHROMOGENIC ASSAYS ON DIAGNOSTIC ACCURACY

Background. Efanesoctocog alfa (FVIII-ULTRA) represents a paradigm shift in hemophilia. A treatment as a first-in-class recombinant factor VIII engineered for high, sustained activity. Due to its unique structural modifications—including the fusion of the D’D3 domain of von Willebrand factor and XTEN polypeptides—the m...

A. Strangio · 0 citations
Oct 2026

Precision and Trueness Verification of Routine Biochemistry Tests using CLSI EP15-A3.

BACKGROUND Method verification is a fundamental requirement to ensure reliable test results in diagnostic and therapeutic processes. This study aimed to verify the precision and trueness of routine biochemistry assays on the Beckman Coulter AU680 analyzer according to the Clinical and Laboratory Standards Institute (CL...

M. Yardim, Levent Deniz · 0 citations
Oct 2026

B-302 Body Fluids as Complex Analytical Metrices: Challenges in Validation and Analytical Performance of Automated Biochemistry Analyzers

Analysis of body fluids in clinical laboratories provides important information for diagnostic and therapeutic decision-making. However, evaluating analytical performance in body fluids remains challenging, as these complex matrices are rarely validated by manufacturers during product development. In this context...

S. Tufik, Kelly Donato, Mylena Culosso et al. · 0 citations
Open access Sep 2026

Method Comparison of Three Automated D-Dimer Assays

Background and Objective: D-dimer results differ across analytical platforms, which may affect their clinical interpretation. This study aimed to compare the analytical agreement and threshold-based classification of three routinely used D-dimer analyzers. Methods: Of 150 consecutive residual citrated plasma specimens,...

Bağnu Dündar, Betül Özbek Kurtul, B. Badilli et al. · 0 citations