To address the difficulty in accurately characterizing the fault current response of renewable energy grid-connected devices during high-/low-voltage ride-through, this paper proposes a fault current response modeling and parameter identification method based on adaptive nonlinear compensation. First, with the fault voltage and pre-fault operating point as input variables, a basic quadratic equivalent model is established to describe the main variation characteristics of active and reactive currents during high-/low-voltage ride-through. Second, nonlinear compensation terms are introduced into the basic model to correct the response deviation caused by the simplification of fast electromagnetic control links in the electromechanical transient equivalent process, thereby improving the representation capability of the model for complex fault current characteristics. Furthermore, considering that the structural parameters of the nonlinear compensation terms are difficult to directly identify using the traditional least squares method, a differential evolution–ridge regression (DE–Ridge) hierarchical identification method is proposed. In this method, the differential evolution algorithm is used in the outer layer to adaptively optimize the nonlinear structural parameters, while ridge regression is used in the inner layer to solve the corresponding linear coefficients. Case study results show that, compared with the traditional quadratic equivalent model and the fixed nonlinear compensation model, the proposed method further reduces the fault current identification error on the validation set and improves the identification accuracy and generalization capability of fault current responses during high-/low-voltage ride-through.
To address the issues of excessive fault current, insufficient voltage support, and frequency oscillations in grid-forming converters during power grid short-circuit faults, this paper establishes a fault ride-through test model based on the principle of impedance voltage division and analyzes the fault transient chara...
: The deployment of grid-forming converters (GFMC) in weak-grid renewable energy stations can provide voltage support for grid-following converters (GFLC). However, the coupling between the two types of converters may cause the voltage-support capability of the GFMC to be constrained by its overcurrent capacity during...
Yuxuan Chen, Ying-Qi Yi, Meng-Yan Ni et al.· Energy Engineering· 0 citations
Aiming at the problems of intelligent ship inductive power transfer (IPT) systems under complex marine operating conditions, such as susceptibility to parameter perturbations and power device faults, which result in low modeling accuracy, slow dynamic response and poor post-fault stability, this paper investigates an i...
Yuan Li, P. Sun, Haiyan Zeng et al.· Journal of Marine Science an...· 0 citations
Grid-forming converters are essential for low-inertia power systems. However, their semiconductor current and junction-temperature limits make them vulnerable to protection-triggered blocking and thermal overstress during severe voltage sags. Existing control methods still struggle to suppress fault-instant current sur...
Ye Tao, Tao Lu, Yue Yu et al.· Fractal and Fractional· 0 citations
The multi-infeed short-circuit ratio (MSCR) is widely used to characterize the steady-state strength of AC receiving systems with multiple line-commutated converter high-voltage direct-current (LCC-HVDC) infeeds. Its rated-power denominator, however, does not describe the disturbance actually imposed during converter b...
Fan Li, Ya-Han Dong, Ji-Shuo Qin et al.· Energies· 0 citations
The doubly fed induction generator (DFIG) dominates the wind energy market, yet its direct stator-to-grid connection makes it vulnerable to grid faults, creating a tension between hardware self-protection and grid-code fault ride-through (FRT) compliance. This paper presents the modelling and FRT analysis of a 9 MW DFI...
Muhammed Anaz Khan, Abdullatif Hakami, Abdulrahman Salem Ali Alghamdi et al.· Wind· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.