Aug 2026· Stomatologiia· Vol 105 4, pp.
11-18
· 0 citations· 17 references
Medicine
TL;DR
The use of cylindrical implants with non-aggressive threads when working in low density bone both when using spiral or stepped drills, is characterized by low values of torque and stability quotient.
Abstract
Objective
To investigate the values of torque and implant stability quotient of implants with non-aggressive and «active» threads placed using standard spiral and stepped drills.
MATERIAL AND
Methods
As the experimental model was used pig's breastbone. Forty implants were divided in two groups which included 10 implants of each type according to thread design. In the first group bone site preparation was conducted with spiral drills, in the second one - using stepped drill. Peek torque values were measured with surgical motor and dynamometric key and to assess implant stability quotient was used Osstell device with Smartpeg and Multipeg pins.
Results
In the first group, there was no significant difference using any type of implant. In the second group, there was a significant increase in the studied parameters during the use of implants with «active» threads with a stepped drill. Torque values increased in 1.7 times. The increase in stability quotient for both Smartpeg and Multipeg pins in average was 8% and 7% respectively. When comparing cylindrical implants with non-aggressive threads with standard drills and conical implants with «active» threads with a stepped drill, the increase of maximum torque and stability quotient was 80%, 8% and 7% respectively.
Conclusion
The use of cylindrical implants with non-aggressive threads when working in low density bone both when using spiral or stepped drills, is characterized by low values of torque and stability quotient. In low density bone the placement of conical implants with «active» threads using a stepped drill is effective.
Underpreparation appears a viable technique to improve primary stability, nevertheless it might be insufficient to reach the threshold of immediate loading suitability in low density bone.
Neither the choice of drilling technique nor the implant macrogeometry significantly influences insertion torque or stability levels in regions of low bone density in this randomized controlled clinical study.
Worood A Akram, S. Bede· The Journal of craniofacial...· 0 citations
PURPOSE
Dental implants are a widely used and effective method for tooth replacement, yet complications such as abutment screw loosening remain a challenge. The aim of this study was to investigate the effect of different abutments, connection types and restoration types on abutment screw loosening.
MATERIALS AND MET...
Saman Savabi, F. Nejatidanesh, G. Savabi et al.· The International Journal of...· 0 citations
The use of sequential osseodensification protocols yielded superior mechanical stability parameters, specifically in IT and RT, in synthetic (polyurethane) bone models, but improvements in ISQ were predominantly noted in the denser type III model.
Silvio Yoshiaki Okagawa, A. D. de Souza, P. D. de Carvalho et al.· International Journal of Den...· 0 citations
The dissociation between insertion torque and 90-day stability indicates that secondary stability is governed by factors beyond initial mechanical engagement, and suggests a potential long-term biomechanical difference warranting further study.
Ahmed Elkattan, Mónica Blázquez-Hinarejos, H. Assiri et al.· European Journal of Dentistr...· 0 citations
The enhanced insertion torque, higher implant stability quotient, greater pull-out resistance, and increased removal torque suggest that variable pitch implant designs may improve primary stability in compromised bone conditions.
Smitha Sharan, K. Viswaja, Santoshi Kumari V et al.· European Journal of Prosthod...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.