Skip to content

[The values of torque and primary stability of different types of dental implants depending on drill design].

Aug 2026 · Stomatologiia · Vol 105 4, pp. 11-18 · 0 citations · 17 references
Medicine

TL;DR

The use of cylindrical implants with non-aggressive threads when working in low density bone both when using spiral or stepped drills, is characterized by low values of torque and stability quotient.

Abstract

Objective

To investigate the values of torque and implant stability quotient of implants with non-aggressive and «active» threads placed using standard spiral and stepped drills. MATERIAL AND

Methods

As the experimental model was used pig's breastbone. Forty implants were divided in two groups which included 10 implants of each type according to thread design. In the first group bone site preparation was conducted with spiral drills, in the second one - using stepped drill. Peek torque values were measured with surgical motor and dynamometric key and to assess implant stability quotient was used Osstell device with Smartpeg and Multipeg pins.

Results

In the first group, there was no significant difference using any type of implant. In the second group, there was a significant increase in the studied parameters during the use of implants with «active» threads with a stepped drill. Torque values increased in 1.7 times. The increase in stability quotient for both Smartpeg and Multipeg pins in average was 8% and 7% respectively. When comparing cylindrical implants with non-aggressive threads with standard drills and conical implants with «active» threads with a stepped drill, the increase of maximum torque and stability quotient was 80%, 8% and 7% respectively.

Conclusion

The use of cylindrical implants with non-aggressive threads when working in low density bone both when using spiral or stepped drills, is characterized by low values of torque and stability quotient. In low density bone the placement of conical implants with «active» threads using a stepped drill is effective.

View source

Similar papers

Aug 2026

The Effect of Osseodensification and Conventional Implant Site Preparation on Implant Stability of Tapered and Cylindrical Dental Implants: A Randomized Controlled Study.

Neither the choice of drilling technique nor the implant macrogeometry significantly influences insertion torque or stability levels in regions of low bone density in this randomized controlled clinical study.

Worood A Akram, S. Bede · 0 citations
Aug 2026

Screw Loosening and Torque Loss of Zirconia-Based Implant- Supported Dental Prostheses: A Retrospective Clinical Study.

PURPOSE Dental implants are a widely used and effective method for tooth replacement, yet complications such as abutment screw loosening remain a challenge. The aim of this study was to investigate the effect of different abutments, connection types and restoration types on abutment screw loosening. MATERIALS AND MET...

Saman Savabi, F. Nejatidanesh, G. Savabi et al. · 0 citations
Open access Jan 2026

Effect of Undersized Drilling and Sequential Osseodensification on Primary Implant Stability in Simulated Bone Types III and IV: An In Vitro Study

The use of sequential osseodensification protocols yielded superior mechanical stability parameters, specifically in IT and RT, in synthetic (polyurethane) bone models, but improvements in ISQ were predominantly noted in the denser type III model.

Silvio Yoshiaki Okagawa, A. D. de Souza, P. D. de Carvalho et al. · 0 citations
Open access Aug 2026

Insertion Torque Value and Implant Stability Quotient of Bone-Level Versus Tissue-Level Dental Implants: A Pilot Randomized Clinical Trial

The dissociation between insertion torque and 90-day stability indicates that secondary stability is governed by factors beyond initial mechanical engagement, and suggests a potential long-term biomechanical difference warranting further study.

Ahmed Elkattan, Mónica Blázquez-Hinarejos, H. Assiri et al. · 0 citations
Open access Sep 2026

Biomechanical evaluation of variable pitch and tapered thread dental implants in simulated low-density bone conditions: An in-vitro comparative study

The enhanced insertion torque, higher implant stability quotient, greater pull-out resistance, and increased removal torque suggest that variable pitch implant designs may improve primary stability in compromised bone conditions.

Smitha Sharan, K. Viswaja, Santoshi Kumari V et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.