Skip to content

Twelve-Year Outcomes of Immediately Functionally Loaded Single Implants: A Prospective Multicenter Clinical Study.

Aug 2026 · International Journal of Prosthodontics · Vol 0 0, pp. 1-25 · 0 citations
Medicine

TL;DR

Immediate functional loading of single implants demonstrated favorable long-term clinical performance, limited biologic and prosthetic complications, and excellent peri-implant bone stability.

Abstract

Purpose

To evaluate the long-term survival, complications and peri-implant marginal bone loss (PIMBL) associated with immediately functionally loaded single implants after 12 years of follow-up.

Methods

Forty-six patients treated at six clinical centers received single implants placed either in healed ridges or fresh extraction sockets and restored under immediate functional loading. All implants were placed according to a standardized surgical and prosthetic protocol and followed for 12 years. Primary outcome measures included implant survival, biologic and prosthetic complications, and PIMBL.

Results

Fifty-seven implants were placed, including 47 in healed sites and 10 in extraction sockets. Six patients (seven implants) were lost to follow-up. After 12 years, only two implant failures were recorded, resulting in survival rates of 95.7% at the patient level and 96.5% at the implant level. Biologic complications occurred in 4.3% of patients and 3.5% of implants, whereas prosthetic complications affected 15.2% of patients and 12.2% of implants. Mean PIMBL at 12 years was 0.41 ± 0.18 mm, with comparable values observed in healed sites and extraction sockets.

Conclusions

Immediate functional loading of single implants demonstrated favorable long-term clinical performance, limited biologic and prosthetic complications, and excellent peri-implant bone stability. When adequate primary stability and appropriate case selection are achieved, this treatment approach appears to be a predictable option for single-tooth rehabilitation.

View source

Similar papers

Open access Aug 2026

Prospective clinical study to evaluate the survival of two-piece zirconia implants: a single-center study. 36-month results

The 39.1% early failure rate within the first 12 months was followed by stable marginal bone levels through 36 months in implants that achieved successful osseointegration, underlining the need for peri-implant maintenance.

M. Jennes, Z. Mao, Ece Atay et al. · 0 citations
Open access Oct 2026

Immediate Versus Early Loading Protocols in Rehabilitation of Fully Edentulous Maxilla: A 5-Year Pilot Randomized Clinical Trial.

OBJECTIVE To compare 5-year outcomes of immediate versus early loading protocols for complete implant-supported fixed dental prostheses in edentulous maxillae. MATERIALS AND METHODS A prospective randomized controlled trial evaluated 24 patients (144 Bone Level Tapered SLActive implants) assigned to immediate loading...

Vecihe Merve Balta Uysal, A. Marković, Tijana Mišić et al. · 0 citations
Aug 2026

Proximal Peri-implant Bone Behavior in Immediately Loaded Extra-Narrow Dental Implants: Retrospective Cohort Study.

PURPOSE To evaluate the proximal bone behavior and 1-year survival rate of immediately loaded Ø2.9 mm narrow-diameter implants. MATERIALS AND METHODS Eighteen immediately loaded implants were retrospectively assessed by standardized radiographic analysis at three time points: T1, immediately after placement; T2, 4-6...

Hiromi Ikeda, Jean Ulhendorf, Ana Toyofuku et al. · 0 citations
Open access Aug 2026

Tilted Versus Axial Dental Implants in Compromised Alveolar Ridges

This study aimed to compare the long-term clinical performance, marginal bone stability, and survival rates of tilted versus axial dental implants placed in compromised alveolar ridges over a 5-year follow-up period, while concurrently evaluating patient-centered treatment outcomes. A cohort of 300 patients who underwe...

Natheer Ayed Jasim · 0 citations
Open access Aug 2026

Clinical performance of a conometric retention system for single implant restorations: 1-year analysis of a prospective multicenter study

The investigated conometric retention system demonstrated high implant and prosthetic survival rates and limited marginal bone changes, however, a clinically relevant incidence of technical complications, including irreversible loss of conometric retention, was observed during the first year of function.

Peter Gehrke, Octavio Weinhold, Pelayo Antuna et al. · 0 citations