Sep 2026· Investigative Ophthalmology and Visual Science· Vol 67, pp. 4· 0 citations· 40 references
Medicine
TL;DR
Non-letter optotypes provide clinically useful and broadly comparable measures of VA at the population level supporting their use in clinical practice or population/clinical studies and wide variability means they cannot be considered interchangeable for individual subjects.
Abstract
Purpose Visual acuity (VA) is a key outcome measure in clinical practice, epidemiological studies, and in clinical trials. However, letter-based charts may disadvantage individuals who are illiterate or are unfamiliar with Latin text, thereby limiting subject participation and complicating comparisons across studies. We compared VA using Early Treatment Diabetic Retinopathy Study (ETDRS) charts for Latin letters, Landolt-C, or Tumbling-E optotypes to determine their association and measurement variability. Methods Seventy-eight patients from an eye clinic underwent VA testing using the various optotypes on an ETDRS logMAR chart. VA was measured with a pinhole (PH), uncorrected, and corrected for the three optotypes, and compared with results in severe VA loss. Regression slopes, coefficients of determination, and limits of agreement (LoA) were determined. Results All three optotype VAs showed a similar response to PH use, with an average improvement of approximately three logMAR lines. For uncorrected VA, Tumbling-E and Landolt-C showed slopes near 1.0 relative to letter VA across a broad range with R2 > 0.93. For corrected VA, slopes were 0.73 (Tumbling-E) and 0.58 (Landolt-C), with R2 ≈0.70. Combining our data with prior studies extended the range to 20/2000 for Landolt C and letter VA, yielding slopes near 1.0 and R2 > 0.94. LoA across comparisons ranged from logMAR ±0.12 to ±0.23. Conclusions Non-letter optotypes provide clinically useful and broadly comparable measures of VA at the population level supporting their use in clinical practice or population/clinical studies. However, the wide variability means they cannot be considered interchangeable for individual subjects.
Differences in stereoacuity are evident across stereotests under simulated conditions of blur, and Random dot tests such as TNO and Optonet are impacted more by blur than Frisby with Optonet showing the greatest sensitivity to blur.
J. Mehta, Anna O'Connor, Roisin Buckels· Strabismus· 0 citations
Clinical relevance: Vernier acuity (VA) is a common clinical metric used to evaluate cortical visual processing and macular health that is relatively independent of typical optical limitations (such as blurring). Background: Past studies have shown that vernier thresholds do not tend to vary according to blur, intensit...
Yaw Buabeng, Billy R. Hammond· Vision· 0 citations
PURPOSE
To compare contrast sensitivity function (CSF) measurements obtained with either Gabor gratings or Sloan letters using the same LCD-based device, to evaluate the reliability of letter-based CSF testing and to establish normative values in a young healthy population.
METHODS
A new computerised chart for psycho...
Assunta Di Vizio, Riccardo Rolandi, A. Duse et al.· Ophthalmic & physiological o...· 0 citations
PURPOSE
The single Maddox rod test (SMRT) is a rapid subjective method for detecting ocular misalignment. In this study, we compared the prism single Maddox rod test (PSMRT) to the prism alternate cover test (PACT) in normal individuals to see if there was any disagreement.
METHODS
Ocular alignment was measured at di...
Victoria Erickson, K. Merrill, Collin M. McClelland et al.· Journal of Binocular Vision...· 0 citations
VA was valid for detecting myopia at the <6/7.5 cutoff for preschool children and Astigmatism and hyperopia, even at high levels, did not consistently impact VA.
M. Ilango, F. C. Adinanto, K. Rose et al.· Strabismus· 0 citations
In children with myopia, the qCSF results were significantly better after refraction correction than those under uncorrected visual acuity and increased linearly with the degree of myopia, whereas in children with hyperopia, the qCSF parameters before and after refraction correction did not differ significantly.
Zhan-Ying Wang, Yu-Hao Ye, Fang Liu et al.· Clinical Ophthalmology· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.