Skip to content
Open access

Using Manganese‐Enhanced DCE‐MRI to Assess Blood‐Cerebrospinal Fluid Barrier Transport

Jul 2026 · Magnetic Resonance in Medicine · Vol 96, pp. 2083 - 2091 · 0 citations · 37 references
Medicine

Abstract

We developed a dynamic, heavily T2‐weighted (hT2w) FLAIR protocol to resolve acute Mn2+ transport kinetics, as a proxy for Ca2+, across the choroid plexus (ChP)—cerebrospinal fluid (CSF) interface, in vivo. By quantifying intercompartmental Mn2+ dynamics, and comparing these with Gd‐DOTA, we sought to characterize blood‐CSF‐barrier (BCSFB)‐mediated tracer transport, combining high in‐plane resolution and 4‐min temporal sampling.

Read PDF

Similar papers

Open access Sep 2026

Feasibility of Spin‐ and Gradient‐Echo Dynamic Susceptibility Contrast MRI for Microvascular Characterization at 7 Tesla

Perfusion MRI, especially dynamic susceptibility contrast (DSC), is vital for glioma diagnosis and monitoring. While gradient‐echo DSC is the current recommended implementation, combined spin‐ and gradient‐echo (SAGE) DSC additionally allows for vessel size imaging (VSI) and has shown feasibility for microvascular char...

Karen N. van der Werff, D. van Dorth, Krishnapriya Venugopal et al. · 0 citations
Open access Sep 2026

High‐Resolution IVIM MRI Characterizes Diffusion–Perfusion Properties of the Parasagittal Dura

ABSTRACT The objectives of this study were to characterize the diffusion–perfusion properties of the parasagittal dura (PSD) using high‐resolution intravoxel incoherent motion (IVIM) MRI and to explore whether PSD‐specific IVIM metrics reflect distinct fluid‐transport‐related signal behavior compared with CSF and brain...

Yi-Jui Liu, Chun-Han Liao, Shin-Lei Peng et al. · 0 citations
Open access Aug 2026

Free‐Breathing Hepatic Oxygen Extraction Fraction (OEF) Mapping Using Radial GESSE

Noninvasive assessment of hepatic oxygenation is relevant for evaluating liver both in acute and long‐term liver pathologies. However, existing methods are limited to single‐slice acquisitions and require breath‐holding. This study aims to develop and evaluate a motion‐robust technique for whole‐liver oxygen extraction...

Ke Zhang, S. Triphan, Felix T. Kurz et al. · 0 citations
Nov 2025

DTI‐ALPS Primarily Reflects White Matter Diffusion Dispersion and Microstructural Heterogeneity in Neurodegeneration: Insights From Multi‐Modal MRI

Factor analysis indicated that DTI-ALPS clustered with MA and ODI rather than forming a distinct factor, suggesting that DTI-ALPS primarily reflects WM diffusion dispersion and heterogeneity rather than glymphatic flow in the context of neurodegeneration.

L. Sacchi, Giovanni Farruggio, Giorgio Bocca et al. · 1 citation
Open access Aug 2026

Multi‐Vendor and Multi‐Site Characterization of 13C Coils for Clinical Studies

A gradient-recalled echo (GRE) sequence is presented alongside an image-based analysis for SNR estimation and QC of 13C coils, advancing the clinical translation of 13C MRS methodologies.

Emil S Christensen, Andreas Clemmensen, E. S. Hansen et al. · 0 citations
Open access Aug 2026

Placental Blood‐Flow Velocity Quantification From Diffusion MRI

Altered placental capillary blood flow is closely linked to obstetric complications, yet quantifying capillary‐scale blood velocity remains challenging with existing imaging methods. This is partially because capillary networks form disordered microvascular beds at the voxel scale, rather than coherent, directional ves...

Zhuang-Jian Yang, D. C. de Oliveira, L. Kerkelä et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.