Skip to content
Open access

Assessing the reliability and validity for metabolic syndrome diagnosis using point-of-care analyzers in a mobile setup - a pilot study

Aug 2026 · BMC Primary Care · Vol 27 · 0 citations · 38 references
Medicine

Abstract

The metabolic syndrome (MetS) is characterized by having three or more of these risk factors: increased blood glucose (Glc), serum triglycerides (TG), blood pressure (BP), waist circumference (WC), and reduced high-density lipoprotein (HDL). Mobile diagnostics using point-of-care (POC) blood analyzers could help identify individuals at risk. This pilot study assessed reliability and validity of MetS risk factor analysis using POC analyzers in a mobile examination unit. Fifty participants (52 ± 7y; 170 ± 10 cm; 80 ± 19 kg, m/f: 21/29) were included for analysis. The mobile examination unit was equipped with different POC analyzers (Alere, LABGEO, CardioChek for Glc, HDL, TG; Quo-Test-A1C Testkit for HbA1c‘). Agreement compared to a reference laboratory (RefLab) was analyzed by Bland-Altman (bias, Limits of Agreement (LoA)), ICC, SEM and McNemar’s test. Test-retest analysis was assessed on two different days (max. two weeks apart) using Spearman’s rho, ICC, test-retest variability (TRV%) and McNemar’s test. Based on the smallest bias and low number of missing values (Glc: -5 [LoA − 25 to 6] mg/dl; TG: 8 [LoA − 58 to 30] mg/dl; HDL: -2 [LoA − 14 to 9] mg/dl), and the highest agreement in MetS diagnosis compared to the results of RefLab, the Alere POC device was chosen. Test-retest reliability (n = 16) for MetS risk factors and HbA1c measured in the mobile setup ranged from poor to excellent with low TRV (0.9–5.8%). Risk factor classification and MetS diagnosis did not differ between measurement days. A mobile setup using the Alere POC analyzer could be used as a valid mobile screening method for MetS to ensure early detection of risk factors.

Read PDF

Similar papers

Open access Aug 2026

Validation of Precision and Accuracy of Point-of-Care Testing Glucose Analyzers with a Standard Laboratory Method (Glucose Oxidase Method)

POCT glucose meters should be used cautiously and primarily for monitoring trends rather than definitive diagnosis or therapeutic decisions, as they have limited reliability for critical clinical decision-making.

E. Nwobodo, N. T. Emmanuel · 0 citations
Open access Aug 2026

Cross-sectional evaluation of two point-of-care glucose meters against the GOD-PAP reference method

Both POCT devices demonstrated acceptable analytical agreement with the GOD-PAP method for blood glucose testing, however, Emtech BG Max 1 exhibited superior precision, lower analytical bias, and higher compliance with ISO 15197:2013, indicating greater reliability for routine clinical use.

Muhammad Jalil Razak, N. Ismi, Marisca Jenice Sanakya et al. · 0 citations
Open access Jul 2026

Blood viscosity as a continuous marker of cardio-metabolic risk burden: a large-scale cross-sectional study of 38,574 adults

Aims Metabolic syndrome (MetS) is diagnosed using fixed thresholds that may not fully reflect the continuous accumulation of cardio-metabolic risk. We investigated whether whole blood viscosity (WBV) increases progressively with increasing MetS burden and explored the relative contribution of individual MetS components...

D. Lee, Byoungduck Han, Hongyup Ahn et al. · 0 citations
Open access Aug 2026

Assessment of cardiometabolic risk using single point insulin sensitivity estimator (SPISE) in pediatric Bardet–Biedl Syndrome: a pilot study

In this single-center pediatric BBS cohort, SPISE tracked continuous MetS burden and showed numerically stronger discrimination for MetS than insulin-derived indices, highlighting the potential utility of SPISE as a feasible tool for cardiometabolic monitoring in syndromic obesity, where laboratory access may be limite...

Tuğçe Kandemir, Melek Yildiz, U. Tercan et al. · 0 citations
2026

CORRELATION BETWEEN POINT-OF-CARE AND LABORATORY-BASED AUTOMATED BLOOD GLUCOSE TESTING

Background:Diabetes mellitus is a growing global health concern, with rising prevalence particularly in low-and middle-income countries. Accurate blood glucose estimation is essential for diagnosis, monitoring, and prevention of complications. While glucometers provide rapid, convenient results at the point ofcare, lab...

Vaaruni Sharma, Ajay K. Puri · 0 citations