The metabolic syndrome (MetS) is characterized by having three or more of these risk factors: increased blood glucose (Glc), serum triglycerides (TG), blood pressure (BP), waist circumference (WC), and reduced high-density lipoprotein (HDL). Mobile diagnostics using point-of-care (POC) blood analyzers could help identify individuals at risk. This pilot study assessed reliability and validity of MetS risk factor analysis using POC analyzers in a mobile examination unit. Fifty participants (52 ± 7y; 170 ± 10 cm; 80 ± 19 kg, m/f: 21/29) were included for analysis. The mobile examination unit was equipped with different POC analyzers (Alere, LABGEO, CardioChek for Glc, HDL, TG; Quo-Test-A1C Testkit for HbA1c‘). Agreement compared to a reference laboratory (RefLab) was analyzed by Bland-Altman (bias, Limits of Agreement (LoA)), ICC, SEM and McNemar’s test. Test-retest analysis was assessed on two different days (max. two weeks apart) using Spearman’s rho, ICC, test-retest variability (TRV%) and McNemar’s test. Based on the smallest bias and low number of missing values (Glc: -5 [LoA − 25 to 6] mg/dl; TG: 8 [LoA − 58 to 30] mg/dl; HDL: -2 [LoA − 14 to 9] mg/dl), and the highest agreement in MetS diagnosis compared to the results of RefLab, the Alere POC device was chosen. Test-retest reliability (n = 16) for MetS risk factors and HbA1c measured in the mobile setup ranged from poor to excellent with low TRV (0.9–5.8%). Risk factor classification and MetS diagnosis did not differ between measurement days. A mobile setup using the Alere POC analyzer could be used as a valid mobile screening method for MetS to ensure early detection of risk factors.
POCT glucose meters should be used cautiously and primarily for monitoring trends rather than definitive diagnosis or therapeutic decisions, as they have limited reliability for critical clinical decision-making.
E. Nwobodo, N. T. Emmanuel· IOASD Journal of Medical and...· 0 citations
Both POCT devices demonstrated acceptable analytical agreement with the GOD-PAP method for blood glucose testing, however, Emtech BG Max 1 exhibited superior precision, lower analytical bias, and higher compliance with ISO 15197:2013, indicating greater reliability for routine clinical use.
Muhammad Jalil Razak, N. Ismi, Marisca Jenice Sanakya et al.· Journal Interdisciplinary He...· 0 citations
Aims Metabolic syndrome (MetS) is diagnosed using fixed thresholds that may not fully reflect the continuous accumulation of cardio-metabolic risk. We investigated whether whole blood viscosity (WBV) increases progressively with increasing MetS burden and explored the relative contribution of individual MetS components...
D. Lee, Byoungduck Han, Hongyup Ahn et al.· Frontiers in Endocrinology· 0 citations
In this single-center pediatric BBS cohort, SPISE tracked continuous MetS burden and showed numerically stronger discrimination for MetS than insulin-derived indices, highlighting the potential utility of SPISE as a feasible tool for cardiometabolic monitoring in syndromic obesity, where laboratory access may be limite...
Tuğçe Kandemir, Melek Yildiz, U. Tercan et al.· Orphanet Journal of Rare Dis...· 0 citations
Background:Diabetes mellitus is a growing global health concern, with rising prevalence particularly in low-and middle-income countries. Accurate blood glucose estimation is essential for diagnosis, monitoring, and prevention of complications. While glucometers provide rapid, convenient results at the point ofcare, lab...
Vaaruni Sharma, Ajay K. Puri· Asian Journal of Medical Res...· 0 citations
POCT glucose measurements show excellent correlation with laboratory auto-analyser results but exhibit systematic and proportional bias, particularly at higher glucose levels, particularly at higher glucose levels.
Ufuoma Ohwo, K. Digban, C. Okafor· Apollo Medicine· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.