Oct 2026· International Conference on Laser, Materials, and Advanced Manufacturing· Vol 14369, pp. 143691S - 143691S-5· 0 citations· 6 references
Engineering
Abstract
Based on the GB/T 12162 series standards and current measurement regulations, this paper systematically investigates the establishment and calibratias the uncertainty assessment of air kerma rate measurements. Key technical aspects including radiation field uniformity (thon methods of X-ray collimated reference radiation fields, as well erapeutic level ±1%), output stability (RSD≤0.3%), and beam axis alignment (≤3°) are analyzed in detail. Implementation approaches for therapeutic and protection level calibrations are discussed. To address the limitations of traditional analytical geometry in complex environments, optimization schemes incorporating Monte Carlo simulation and machine learning technologies are proposed to correct environmental scattering effects and improve calibration accuracy. Through the introduction of Monte Carlo simulation and machine learning technologies, optimization schemes for reducing scattering effects and improving calibration accuracy are proposed. In terms of uncertainty assessment, a mathematical model incorporating calibration factor, stability, and repeatability is established for therapeutic level measurements, yielding a relative expanded uncertainty of Urel = 1.4% (k=2). While the model structure follows GUM guidelines, its practical implementation incorporates refined quantification of previously underestimated components, such as spectral mismatch and scatter contributions, offering an optimized uncertainty budget for high-precision metrology. This work provides theoretical foundation and practical guidance for quality control in radiation metrology laboratories.
The first half-value layer (HVL), defined as the thickness of material required to reduce the x-ray beam intensity (air kerma) to 50%, is a key radiation quality specifier. Although HVL has been measured for decades using ionization chambers and aluminum filters, the detailed measurement procedures and associated uncer...
Aino Tietäväinen, P. Toroi, Bartel Jansen et al.· Metrologia· 1 citation
This study investigates the error propagation in the calibration stage of lifetime based phosphor thermometry and establishes a quantitative framework linking calibration errors to final temperature uncertainty. The results demonstrate that the primary error source originates not from the lifetime measurement, but from...
T. Cai, Zheng Dai, C. Tropea et al.· Measurement science and tech...· 0 citations
INTRODUCTION
Accurate determination of air kerma, tube‑voltage‑related quantities (TV), and half‑value layer (HVL) is essential for reliable dosimetry in X‑ray imaging. X‑ray multimeters (XMMs) are widely used for these measurements; however, their performance depends on spectral characteristics and measurement conditi...
P. Toroi, Viivi Valkama, T. Kaasalainen et al.· Physica medica (Testo stampa...· 0 citations
BACKGROUND
Gamma spectrometry with high-resolution High-Purity Germanium detectors is a widely adopted technique, valued for its excellent energy resolution. It is applied across a range of Radiation Protection activities, including the measurement of low-activity concentrations in environmental samples containing natu...
M. Signoriello, F. Bragato, M. Fornasier et al.· Physica medica (Testo stampa...· 0 citations
Accurate non-contact infrared temperature measurement is essential for industrial monitoring, predictive maintenance, and engineering applications requiring reliable thermal condition assessment. However, measurement accuracy is affected by multiple uncertainty sources, including observation angle, sensor-to-object dis...
N. Irgashev, Nijat R. Zohrabov, A. Namazov· 2026 International Ural Conf...· 0 citations
Laser warning receivers (LWRs) locate laser threat sources by measuring the incident direction of incoming laser radiation. Parametric errors inherent in their optical systems constitute a critical factor that affects angle measurement accuracy. Existing error analysis methods are largely confined to single-factor inve...
Deng-Tian Bai, Meng Chen, Cun-Hui Li et al.· Photonics· 0 citations