Evaluation of the accuracy of a portable glucose meter compared with laboratory-based spectrophotometric methods

2026 · Journal of Medical Biochemistry · Vol 45, pp. 1999-2008 · 0 citations · 46 references

TL;DR

The glucometer demonstrated moderate performance and partial agreement with selected ISO 15197:2015 accuracy limits compared with laboratory-based spectrophotometric methods, but increased variability at higher glucose concentrations limits its applicability in settings requiring high analytical precision.

Abstract

Background: The accuracy of portable blood glucose monitoring systems is critical for the safe management and follow-up of Diabetes Mellitus. This study evaluated the accuracy of a capillary glucose monitoring device compared with laboratory-based spectrophotometric analysis of venous blood according to ADA recommendations and selected ISO 15197:2015 accuracy limits. Methods: A cross-sectional study was conducted using 133 paired venous and capillary blood samples. Glucose concentrations were measured using the Humalyzer 2000 and Mindray BA-88A spectrophotometers and the Prodigy AutoCode® glucometer. Data were analysed using Kruskal-Wallis and Spearman correlation tests, with p<0.05 considered statistically significant. Results: The glucometer reported slightly lower glucose values than the laboratory-based spectrophotometric methods. Correlation showed a weak association with the Humalyzer 2000 (r=0.17) and a moderate association with the Mindray BA-88A (r=0.415). Seventy-four per cent of measurements were within the ISO 15197:2015 acceptance limits compared with the Humalyzer 2000, whereas 92% were within the acceptance limits compared with the Mindray BA-88A for glucose concentrations <100 mg/dL. Bland–Altman analysis showed low systematic bias versus both analysers (-0.44 to -3.89 mg/ dL), although agreement was more consistent with the Mindray BA-88A because of narrower limits of agree ment. Greater variability was observed at higher glucose concentrations, particularly with the Humalyzer 2000. Conclusion: The glucometer demonstrated moderate performance and partial agreement with selected ISO 15197:2015 accuracy limits compared with laboratory-based spectrophotometric methods. Increased variability at higher glucose concentrations limits its applicability in settings requiring high analytical precision; therefore, results should be interpreted with caution.

Read PDF

Similar papers

Open access Aug 2026

Validation of Precision and Accuracy of Point-of-Care Testing Glucose Analyzers with a Standard Laboratory Method (Glucose Oxidase Method)

POCT glucose meters should be used cautiously and primarily for monitoring trends rather than definitive diagnosis or therapeutic decisions, as they have limited reliability for critical clinical decision-making.

E. Nwobodo, N. T. Emmanuel · 0 citations
Open access Aug 2026

Evaluation of Glucose Results Measured by 2 Different Glucometer Brands

Objective: The aim of this study was to retrospectively evaluate the performance of 2 glucometer devices using the accuracy criteria specified in ISO 15197:2015. Methods: Glucose results obtained from Accu-Chek Inform II and Sejoy BG-707 glucometers, which measure according to the glucose dehydrogenase principle, were...

T. Noyan, Murat Cihan, E. Yiğit et al. · 0 citations
Open access Aug 2026

Comparative analysis of enzymatic assay for HbA1c measurement with high performance liquid chromatography

HbA1c is an approved test for the diagnosis and monitoring of diabetes. Several assays are in use worldwide based on chromatography, cation-exchange, enzymatic and immunological principles. High Performance Liquid Chromatography (HPLC) is regarded as the gold standard method while other assays including enzymatic assay...

Gulab Fatima Rani, Hazrat Bilal, Shumaila Jabeen et al. · 0 citations
Open access Sep 2026

Concordance of the analysis of basic biochemical and hematological parameters using a blood gas analyzer compared to laboratory analyses: a retrospective method-comparison study from a tertiary center in Morocco

Introduction: the use of "point-of-care" (POC) monitoring, like blood gas analysis, allows clinicians to measure important variables in real-time, allowing for immediate results to be provided to make rapid decisions. However, the reliability of basic biochemistry and hematology parameters in arterial blood conducted a...

Maaroufi Ayoub, Diai Abdellatif, El Akef Taoufik et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.